Rolling Stock High Temperature Single Core Sheathed Cables 3.6/6 kV EN 50382-2

Rolling Stock application, LSZH, Fire Retardant, high temperature
RO366150HF, 27.12.2019/AP rev.0
Type Approval: – 

 

Print or Download PDF

Description

    

 

Store at:  -10 to +50 °C
Install at:    0 to +50 °CBend minimum: 4 times O.D.
Operate at: -40 to +150 °CBend minimum: 4 times O.D.

Design

Conductor material: Flexible copper wires class 5 or 6 according to HD 383
Insulation :  silicon rubber according to EN 50382-1 (EI 112)
Outer Sheath :  LSZH compound according to EN 50382-1 (EM 107)
Marking :  APS Finland – ww/yy – core size – 3.6/6kV – 150 ºC – P/N – lot – meter marking

 

Chemical & Environmental properties 

Mineral & fuel oil resistance: EN 50305, EN 60811-2-1
Acid & alkali resistance:
EN 50305, EN 60811-2-1
Fluorine free:
  EN 60684-2

Ozone resistance: EN 50305

Fire performances  

EN 50306-2: hazard levels HL1, HL2/HL3, HL4
DIN 5510-2: protection levels 1/2/3/4
BS 6853:  interior use 1a, 1b, II
BS 6853: exterior use 1a, 1b, II
NF F 16-101: F0  

 

Electrical characteristics

Nominal operating Voltage : 3.6/6kV

 

Table of characteristics

P/NCross sectional areaConductor diameter Insulation thicknessOverall diameter
Overall diameterOverall diameter WeightMax conductor resistance (CuTn)Max conductor resistance (Cu)Min. insulation resistance @ 20 deg. CMin. insulation resistance @ 150 deg. C
mm2mmmm, nominalmm, minmm, minmm, maxkg/kmOhm/kmOhm/kmMOhm x kmMOhm x km
RO366150HF0252.51.952.61.49.911.61308.217.988701.70
RO366150HF0404.02.52.61.410.412.21505.094.957501.50
RO366150HF0606.03.02.61.410.912.81803.393.306701.30
RO366150HF100103.92.61.411.813.82401.951.915701.10
RO366150HF160165.02.61.412.815.03001.241.214800.90
RO366150HF250256.42.91.414.717.24100.7950.7804300.80
RO366150HF350357.72.91.415.918.65100.5650.5543800.70
RO366150HF500509.22.91.517.520.56600.3930.3863300.60
RO366150HF7007011.02.91.519.222.48700.2770.2722800.50
RO366150HF9509512.52.91.620.824.311000.2100.2062500.50
RO366150HF12012014.22.91.622.426.213300.1640.1612300.40
RO366150HF15015015.82.91.724.128.216400.1320.1292100.40
RO366150HF18518517.53.21.826.430.919900.1080.1062100.40
RO366150HF24024020.13.41.929.434.426200.08170.08011900.30
RO366150HF30030022.53.41.931.737.131200.06540.06411700.30
RO366150HF40040025.83.42.035.040.941500.04950.04861500.30

 

 

Other standards of reference

EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2)
EN 50266-2-4 + EN 50305; IEC 60332-3-24;
NF C 32-070 2.2 (C1); VDE 0472 Teil 804
EN 50268-2; IEC 61034-2; NF C 32-073 ;
NF C 20-902; NF F 16 101; VDE 0472 Teil 816
EN 50267-2-1; IEC 60754-1; NF C 32-074;
NF C 20-454; VDE 0472 Teil 815
EN 50267-2-2/3; IEC 60754-2; NF C 32-074;
NF C 20-453; VDE 0472 Teil 813
EN 50305; NF X 70-100; NF F 63 808; TM1-04; BS6853
NF F 63 808; BS6853; NF F 16 101

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

 

 

SKU: O492322_, TFL49232_-1 Category: