RE-2X(st)H Cl PiMF/TiMF multipair instrumentation cable 500V HFFR UVR, Fire and Oil resistant

XLPE insulated, Individually & overall screened , LSZH sheathed Fire Resistant Instrumentation cables, EN 50288-7 500 V
CU/MGT+XLPE/ISCR/OSCR/LSZH
RE2XSTHClPVO
Rev. 00 – 22.09.2023 

 

 

Print or Download PDF

Description

   

 

Store at: 0 to +50 °C
Install at: 0 to +50 °CBend minimum: 10 times V.D.
Operate at: -20 to +70 °CBend minimum: 15 times V.D.

Standard of reference 

EN 50228-7, EN 50290-2-27, BS/PAS 5308, EN 60228, IEC 60332-1-2, IEC 60332-3-24, IEC 60331,  IEC 60811-404

 

Design

Conductor material: Bare copper stranded conductors acc. to IEC 60228 class 2
Insulation: XLPE (2X) compound – TS EN 50290-2-29 + fire resistant tape
Core identification:
– pairs:
Black, White (Each numbered)
– triples:
Black, White, 
Red (Each numbered) 
Pairing:
Cores twisted to form a pairs/triples, PES wrapped
Individual screening:
Aluminium Foil in contact with Tinned copper solid drain wire 0,60 mm
Stranding (Laid up): individually screened pairs/triples stranded in layers, PES tape wrapped
Overall screening: Aluminium Foil in contact with Tinned copper drain wire 0,50 mm2 (7×0,30 mm)
Outer Sheath: LSZH (HFFR) compound – EN 50290-2-27, UV and Oil resistant
Outer sheath colour:
Black, Blue , Grey RAL7001 (or on request)

Marking: APS Finland – ww/yy – FIRE RESISTANT RE-2X(st)H Cl PiMF P/T count – HFFR UVR 500V – +70°C – EN50288-7 IEC60332-3-24 IEC60331 – P/N – lot# + meter

 

Environmental properties and Fire Performances

Flame retardant: IEC 60332-1, VDE 0482-332-1-2, BS EN 60332-1-2
Fire retardant: IEC 60332-3-24 Cat.C

Amount of halogen acid gas:
IEC 60754-1, EN 50267-1
Degree of acidity of gases:
IEC 60754-2, EN 50267-2
Smoke density test:
IEC 61034-1, VDE 0482-1034-1/2
Fire resistance
: IEC 60331, VDE 0472-814
Oil resistance: IEC 60811-404

 

Electrical characteristics

Max conductor temperature: +90 °C
Rated Voltage: 500 V
Test voltage: 2,0 kV AC 1 min.
Insulation resistance: min. 1000 MΩ.km

Capacitance (nF/km) : max. 150 nF/km

Cross section (mm2)0.500.751.01.31.52.5
Conductor IEC 60228 class 27x0,307x0,377x0,437x0,507x0,527x0,67
Conductor resistance max.(Ω/km)36.024.518.114.512.17.41
Insulation thickness min.(mm)0.440.440.440.440.44.53
Insulation thickness nom.(mm)0.600.60.60.60.60.7
L/R Ratio (µH/Ω) 252525404060
 

Ordering and delivery information

Cable typeProduct codeCopper weight (kg/km)Outer diameter (mm)Approx. weight (kg/km)
48x2x0,50RE2XSTHClPVO48P050 584.245.91820
1x2x1,0RE2XSTHClPVO1P1023.48.370
5x2x1,0RE2XSTHClPVO5P10112.918.5320
10x2x1,0RE2XSTHClPVO10P100.6027.0600
20x2x1,0RE2XSTHClPVO20P102535.01120
1x2x1.3RE2XSTHClPVO1P1330.08.784
4x2x1.3RE2XSTHClPVO4P13117.618.2330
12x2x1.3RE2XSTHClPVO12P13343.729.6850
2x2x1.5RE2XSTHClPVO2P1564.715.5230
10x2x1.5RE2XSTHClPVO10P15305.729.5800
20x2x1.5RE2XSTHClPVO20P15612.338.51500
2x2x2.5RE2XSTHClPVO2P25102.718.2330

 

Every effort has been put so that this document is most reliable and free from errors. However, APS Cables & Connectors Oy cannot be considered responsible for any mistake in this document and users should consult APS Cables & Connectors Oy for any information needed. APS Cables & Connectors Oy reserves the right to make changes to the documents at any time, without prior notice.

 

SKU: RE2XSTHClPVO Categories: ,