Description
Store at : -40 to +70 °C
Install at : -10 to +50 °C, Bend minimum : 20 times O.D.
Operate at : -40 to +70 °C, Bend minimum : 15 times O.D.
Pull maximum : 2000N
Crush maximum : 3000N/100mm
Impact maximum : 20J
Cable weight : 240 kg/km
Design
Bare fiber : 9/125/250 Single Mode or 50/125/250 OM2, OM3, OM4, OM5 or 62.5/125/250 OM1
Buffer : Loose tube (Ø2.2mm) filled with jelly, housing up to 12 fibers
Colour code : See table
Fire protection : A fire barrier is applied over every single tube housing fibers
Central member : Steel rope with LSZH sheath
Cable core : Loose tubes and fillers (when necessary) are stranded around the central member. The core is wrapped by a tape.
Inner sheath : Black SHF1 material 1.0mm thick. Nominal outer diameter 10.1mm.
Armour : tinned copper wire braid. Coverage ≥85%.
Outer jacket : Black SHF1 material 1.2mm thick. Nominal outer diameter 13.5mm.
Marking : APS Finland ww/mm – Fiber Optic Cable QFOI “fiber count and type” – SHF1 IEC60332-3-22 Cat.A IEC60331-25 – lot + meter
Environmental properties and Fire Performances
Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : IEC 60331-25 (750°C, 3 hours – 1000°C, 3 hours)
Oil resistant : intermittent splash – permanent resistance available upon request
Water penetration: IEC 60794-1-2-F5-B (loose tubes)
Water absorption: IEC60811-402 (70°C, 240hrs, increase of weight <7.5mg/cm²)
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Ordering and delivery information
Fiber count | SM | OM1 | OM1+ | OM2 | OM3 | OM4 | OM5 | Packaging |
---|---|---|---|---|---|---|---|---|
2 | OQFCI02S21T | OQFCI02M11T | OQFCI02ME1T | OQFCI02M21T | OQFCI02M31T | OQFCI02M41T | OQFCI02M51T | drum 2000m (+/-5%) |
4 | OQFCI04S21T | OQFCI04M11T | OQFOI04ME1T | OQFCI04M21T | OQFCI04M31T | OQFCI04M41T | OQFCI04M51T | drum 2000m (+/-5%) |
6 | OQFCI06S21T | OQFCI06M11T | OQFOI06ME1T | OQFCI06M21T | OQFCI06M31T | OQFCI06M41T | OQFCI06M51T | drum 2000m (+/-5%) |
8 | OQFCI08S21T | OQFCI08M11T | OQFOI08ME1T | OQFCI08M21T | OQFCI08M31T | OQFCI08M41T | OQFCI08M51T | drum 2000m (+/-5%) |
12 | OQFCI12S21T | OQFCI12M11T | OQFOI12ME1T | OQFCI12M21T | OQFCI12M31T | OQFCI12M41T | OQFCI12M51T | drum 2000m (+/-5%) |
24 | OQFCI24S21T | OQFCI24M11T | OQFOI24ME1T | OQFCI24M21T | OQFCI24M31T | OQFCI24M41T | OQFCI24M51T | drum 2000m (+/-5%) |
48 | OQFCI48S21T | OQFCI48M11T | OQFOI48ME1T | OQFCI48M21T | OQFCI48M31 | OQFCI48M41T | OQFCI48M51T | drum 2000m (+/-5%) |
Colour code of fibers
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
---|---|---|---|---|---|---|---|---|---|---|---|
Blue | Orange | Green | Brown | Grey | White | Red | Black | Yellow | Violet | Pink | Aqua |
Colour code of tubes
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | Fillers |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Blue | Orange | Green | Brown | Grey | White | Red | Black | Yellow | Violet | Pink | Aqua | Black |
Other standards of reference
IEC 60092-370 | Electrical installations in ships: Guidance on the selection of cables for telecommunication and data. |
DNV TAP 827.50/1 | Type Approval Program - Optical Fibre Cables |
ABS SVR | Rules for building and classing. Steel Vessels. |
ABS SMR | Rules for building and classing. Steel vessels under 90 meters. |
IEC 60793 | General specifications for both multimode and single-mode optical fibres |
IEC 60794 | general specifications for optical fibres cables |