Description
Store at : -40 to +70 °C
Install at : -10 to +50 °C, Bend minimum : 20 times O.D.
Operate at : -40 to +90 °C, Bend minimum : 15 times O.D.
Pull maximum : 2000N
Crush maximum : 3000N/100mm
Impact maximum : 20J
Cable weight : 250 kg/km
Design
Bare fiber : 250µm
Buffer : Loose tube (Ø2.2mm) filled with jelly, housing up to 12 fibers
Colour code : See table
Fire protection : A fire barrier is applied over every single tube housing fibers
Central member : Steel rope with LSZH sheath
Cable core : Loose tubes and fillers (when necessary) are stranded around the central member. The core is wrapped by a tape.
Inner sheath : Black SHF1 material 1.0mm thick. Nominal outer diameter 10.0mm.
Armour : tinned copper wire braid. Coverage ≥85%.
Outer jacket : Black SHF2 material 1.2mm thick. Nominal outer diameter 13.5mm.
Marking : APS Finland – QFOU – FIBER OPTIC CABLE [Fibre count and type] – IEC 60331-25 [1000°C 180 min] – IEC 60332-3-22 – Lot no + meter marking – [A]
Environmental properties and Fire Performances
Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : IEC 60331-25 (@750°C 3hrs < 1 dB/fiber, @1000°C 3hours < 1,5 dB/fiber)
Ozone resistant : IEC 60811-403
Oil, fuel and hydrocarbon resistant : IEC60811
Water penetration: IEC 60794-1-2-F5-B (loose tubes)
Water absorption: IEC60811-402 (70°C, 240hrs, increase of weight <7.5mg/cm²)
SHF2 : IEC 60092-360 (IEC 60092-359:1987-03)
UV resistant : ASTM-D-2565-16 (720 hrs, max elongation change +/-40%)
Cold bend : CSA 22/2 No.0.3-01 210.2M90 @ -40°C
Ordering and delivery information
Fiber count | SM | OM1 | OM1+ | OM2 | OM3 | OM4 | Packaging |
---|---|---|---|---|---|---|---|
2 | OQFOU02S2 | OQFOU02M1 | OQFOU02ME | OQFOU02M2 | OQFOU02M3 | OQFOU02M4 | drum 2000m (+/-5%) |
4 | OQFOU04S2 | OQFOU04M1 | OQFOU04ME | OQFOU04M2 | OQFOU04M3 | OQFOU04M4 | drum 2000m (+/-5%) |
6 | OQFOU06S2 | OQFOU06M1 | OQFOU06ME | OQFOU06M2 | OQFOU06M3 | OQFOU06M4 | drum 2000m (+/-5%) |
8 | OQFOU08S2 | OQFOU08M1 | OQFOU08ME | OQFOU08M2 | OQFOU08M3 | OQFOU08M4 | drum 2000m (+/-5%) |
12 | OQFOU12S2 | OQFOU12M1 | OQFOU12ME | OQFOU12M2 | OQFOU12M3 | OQFOU12M4 | drum 2000m (+/-5%) |
24 | OQFOU24S2 | OQFOU24M1 | OQFOU24ME | OQFOU24M2 | OQFOU24M3 | OQFOU24M4 | drum 2000m (+/-5%) |
48 | OQFOU48S2 | OQFOU48M1 | OQFOU48ME | OQFOU48M2 | OQFOU48M3 | OQFOU48M4 | drum 2000m (+/-5%) |
72 | OQFOU72S2 | OQFOU72M1 | OQFOU72ME | OQFOU72M2 | OQFOU72M3 | OQFOU72M4 | drum 2000m (+/-5%) |
Colour code of fibers
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
---|---|---|---|---|---|---|---|---|---|---|---|
Blue | Orange | Green | Brown | Grey | White | Red | Black | Yellow | Violet | Pink | Aqua |
Colour code of tubes
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | Fillers |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Blue | Orange | Green | Brown | Grey | White | Red | Black | Yellow | Violet | Pink | Aqua | Black |
Other standards of reference
IEC 60092-370 | Electrical installations in ships: Guidance on the selection of cables for telecommunication and data. |
DNV TAP 827.50/1 | Type Approval Program - Optical Fibre Cables |
ABS SVR | Rules for building and classing. Steel Vessels. |
ABS SMR | Rules for building and classing. Steel vessels under 90 meters. |
IEC 60793 | General specifications for both multimode and single-mode optical fibres |
IEC 60794 | general specifications for optical fibres cables |