Select Page

MOG

MOG

QFCB / QFOB Armoured MUD NEK606 Fire Resistant IEC60331-25, Fire Retardant IEC60332-3-22 Cat.A

Up to 48 cores, metallic armoured, LSZH, MUD Resistant NEK606, Fire Resistant & Fire Retardant
OQFCI0_U, 15.05.2014/AP rev.5
Type Approval: DNV-GL TAE00002VD 

 

Description

 

    

 

Store at : -40 to +70 °C
Install at : -10 to +50 °C, Bend minimum : 20 times O.D.
Operate at : -40 to +70 °C, Bend minimum : 15 times O.D.
Pull maximum : 2000N
Crush maximum : 3000N/100mm
Impact maximum : 20J
Cable weight : 260 kg/km

 

 

Design

Bare fiber : 250µm
Buffer : Loose tube (Ø2.2mm) filled with jelly, housing up to 12 fibers
Colour code : See table
Fire protection : A fire barrier is applied over every single tube housing fibers
Central member : Steel rope with LSZH sheath
Cable core : Loose tubes and fillers (when necessary) are stranded around the central member. The core is wrapped by a tape.
Inner sheath : Black SHF1 material 1.0mm thick. Nominal outer diameter 10.1mm.
Armour : Galvanized steel, bronze or tinned copper wire braid. Coverage ≥85%.
Outer jacket : Black LSZH Fire Retardant material, MUD Resistant 1.5mm thick. Nominal outer diameter 13.5mm.
Marking : APS Finland ww/yy – Fiber Optic Cable QF_B “fiber count and type” – SHF2 MUD RESISTANT NEK606 IEC60332-3-22 Cat A – lot + m

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : IEC 60331-25
Ozone resistant : IEC60811-2-1, DIN VDE 0472 part 805 B
Weather resistant : ASTM G 154, EN 11507
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC60811, IRM 903
MUD resistant : NEK606:2009, IEC60092-350
Water absorption : IEC60811-1-3
Water penetration : IEC 60794-1-2-F5-B (inner core only)
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Cold bend & impact : CSA C22.2

 

 

 

Ordering and delivery information

Fiber countSMOM1OM1+OM2OM3OM4Packaging
2OQFCI02S2UOQFCI02M1UOQFCI02MEUOQFCI02M2UOQFCI02M3UOQFCI02M4Udrum 2000m (+/-5%)
4OQFCI04S2UOQFCI04M1UOQFCI04MEUOQFCI04M2UOQFCI04M3UOQFCI04M4Udrum 2000m (+/-5%)
8OQFCI08S2UOQFCI08M1UOQFCI08MEUOQFCI08M2UOQFCI08M3UOQFCI08M4Udrum 2000m (+/-5%)
12OQFCI12S2UOQFCI12M1UOQFCI12MEUOQFCI12M2UOQFCI12M3UOQFCI12M4Udrum 2000m (+/-5%)
24OQFCI24S2UOQFCI24M1UOQFCI24MEUOQFCI24M2UOQFCI24M3UOQFCI24M4Udrum 2000m (+/-5%)
48OQFCI48S2UOQFCI48M1UOQFCI48MEUOQFCI48M2UOQFCI48M3UOQFCI48M4Udrum 2000m (+/-5%)

Note : for tinned copper braid add “T” at the end of the P/N, for bronze braid add “B” at the end of the P/N.

 

Colour code of fibers

010203040506070809101112
WhiteRedYellowGreenBlueGreyBrownBlackVioletTurquoiseOrangePink

 

Colour code of tubes

TubeType A Type B     
2 fibers4 fibers8 fibers12 fibers24 fibers48 fibers
1Red (12 fibers)Red (2 fibers)Red (2 fibers)Red (4 fibers)Red (4 fibers)Red (6 fibers)Red (12 fibers)
2Green (24 fibers)FillerGreen (2 fibers)Green (4 fibers)Green (4 fibers)Green (6 fibers)Green (12 fibers)
3Natural (36 fibers)FillerFillerFillerNatural (4 fibers)Natural (6 fibers)Natural (12 fibers)
4Natural (48 fibers)FillerFillerFillerFillerNatural (6 fibers)Natural (12 fibers)
5- (*)- (*)- (*)- (*)- (*)- (*)- (*)
6- (*)- (*)- (*)- (*)- (*)- (*)- (*)
(*) filler only in case of 6 elements design

Other standards of reference

IEC 60092-370Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.50/1Type Approval Program - Optical Fibre Cables
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
IEC 60793General specifications for both multimode and single-mode optical fibres
IEC 60794general specifications for optical fibres cables
Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.