Description
Store at : -40 to +70 °C
Install at : -10 to +50 °C, Bend minimum : 20 times O.D.
Operate at : -40 to +70 °C, Bend minimum : 15 times O.D.
Pull maximum : 2000N
Crush maximum : 3000N/100mm
Impact maximum : 20J
Cable weight : 260 kg/km
Design
Bare fiber : 250µm
Buffer : Loose tube (Ø2.2mm) filled with jelly, housing up to 12 fibers
Colour code : See table
Fire protection : A fire barrier is applied over every single tube housing fibers
Central member : Steel rope with LSZH sheath
Cable core : Loose tubes and fillers (when necessary) are stranded around the central member. The core is wrapped by a tape.
Inner sheath : Black SHF1 material 1.0mm thick. Nominal outer diameter 10.1mm.
Armour : Galvanized steel, bronze or tinned copper wire braid. Coverage ≥85%.
Outer jacket : Black LSZH Fire Retardant material, MUD Resistant 1.5mm thick. Nominal outer diameter 13.5mm.
Marking : APS Finland ww/yy – Fiber Optic Cable QF_B “fiber count and type” – SHF2 MUD RESISTANT NEK606 IEC60332-3-22 Cat A – lot + m
Environmental properties and Fire Performances
Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : IEC 60331-25
Ozone resistant : IEC60811-2-1, DIN VDE 0472 part 805 B
Weather resistant : ASTM G 154, EN 11507
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC60811, IRM 903
MUD resistant : NEK606:2009, IEC60092-350
Water penetration: IEC 60794-1-2-F5-B (loose tubes)
Water absorption: IEC60811-402 (70°C, 240hrs, increase of weight <7.5mg/cm²)
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Cold bend & impact : CSA C22.2
Ordering and delivery information
Fiber count | SM | OM1 | OM1+ | OM2 | OM3 | OM4 | Packaging |
---|---|---|---|---|---|---|---|
2 | OQFCI02S2U | OQFCI02M1U | OQFCI02MEU | OQFCI02M2U | OQFCI02M3U | OQFCI02M4U | drum 2000m (+/-5%) |
4 | OQFCI04S2U | OQFCI04M1U | OQFCI04MEU | OQFCI04M2U | OQFCI04M3U | OQFCI04M4U | drum 2000m (+/-5%) |
6 | OQFCI06S2U | OQFCI06M1U | OQFCI06MEU | OQFCI06M2U | OQFCI06M3U | OQFCI06M4U | drum 2000m (+/-5%) |
8 | OQFCI08S2U | OQFCI08M1U | OQFCI08MEU | OQFCI08M2U | OQFCI08M3U | OQFCI08M4U | drum 2000m (+/-5%) |
12 | OQFCI12S2U | OQFCI12M1U | OQFCI12MEU | OQFCI12M2U | OQFCI12M3U | OQFCI12M4U | drum 2000m (+/-5%) |
24 | OQFCI24S2U | OQFCI24M1U | OQFCI24MEU | OQFCI24M2U | OQFCI24M3U | OQFCI24M4U | drum 2000m (+/-5%) |
48 | OQFCI48S2U | OQFCI48M1U | OQFCI48MEU | OQFCI48M2U | OQFCI48M3U | OQFCI48M4U | drum 2000m (+/-5%) |
Note : for tinned copper braid add “T” at the end of the P/N, for bronze braid add “B” at the end of the P/N.
Colour code of fibers
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
---|---|---|---|---|---|---|---|---|---|---|---|
Blue | Orange | Green | Brown | Grey | White | Red | Black | Yellow | Violet | Pink | Aqua |
Colour code of tubes
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | Fillers |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Blue | Orange | Green | Brown | Grey | White | Red | Black | Yellow | Violet | Pink | Aqua | Black |
Other standards of reference
IEC 60092-370 | Electrical installations in ships: Guidance on the selection of cables for telecommunication and data. |
DNV TAP 827.50/1 | Type Approval Program - Optical Fibre Cables |
ABS SVR | Rules for building and classing. Steel Vessels. |
ABS SMR | Rules for building and classing. Steel vessels under 90 meters. |
IEC 60793 | General specifications for both multimode and single-mode optical fibres |
IEC 60794 | general specifications for optical fibres cables |