Description
Store at : -40 to +70 °C
Install at : -5 to +50 °C, Bend minimum : 15 times O.D.
Operate at : -40 to +70 °C, Bend minimum : 10 times O.D.
Pull maximum : 2500N
Crush maximum : 3000N/100mm
Impact maximum : 10J
Design
Bare fiber : 250µm
Buffer : Loose tube (Ø2.8mm up to 12 fibers, Ø3.5mm 16-24) filled with jelly, housing up to 24 fibers
Colour code : See table
Fire protection : mica tape wrapping.
Dielectric armour : anti rodent glass yarns.
Outer sheath : red fire retardant LSZH SHF2-MUD material, typical thickness 1.0mm.
Marking : APS Finland ww/mm – QFAI UNI MUD (QFAB) – FIBER OPTIC CABLE [Fibre type] – IEC 60331-25 [1000°C 90min] – IEC 60332-3-22 – Lot no + meter[A]
Environmental properties and Fire Performances
Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : IEC 60331-25 (1000°C, 90 minutes)
Ozone resistant : IEC60811-2-1, DIN VDE 0472 part 805 B
Weather resistant : ASTM G 154, EN 11507
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC60811, IRM 903
MUD resistant : NEK606:2009, IEC60092-350
Water absorption : IEC60811-1-3
Water penetration : IEC 60794-1-2-F5-B (inner core only)
UV resistant : ASTM G 154 IEC 60068-2-5
Cold bend & impact : CSA C22.2
Ordering and delivery information
Fiber count | Outer diameter (mm) | Weight (kg/km) | P/N | Packaging |
---|---|---|---|---|
2 | 8.0 | 60 | OQFAB02 ff | drum 2000m (+/-5%) |
4 | 8.0 | 60 | OQFAB04 ff | drum 2000m (+/-5%) |
8 | 8.0 | 60 | OQFAB08 ff | drum 2000m (+/-5%) |
12 | 8.0 | 60 | OQFAB12 ff | drum 2000m (+/-5%) |
16 | 9.5 | 70 | OQFAB16 ff | drum 2000m (+/-5%) |
24 | 9.5 | 70 | OQFAB24 ff | drum 2000m (+/-5%) |
ff = S2 for G652D, A1 for G657A1, M1 for OM1, M2 for OM2, M3 for OM3, M4 for OM4, M5 for OM5. |
Colour code of fibers
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
Natural | Red | Green | Yellow | Brown | Blue | Violet | Orange | Grey | White | Black | Pink |
13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 |
Turquoise | Red/black | Green/black | Yellow/black | Brown/black | Blue/black | Violet/black | Orange/black | Grey/black | White/black | Pink/black | Turquoise/black |
Other standards of reference
IEC 60092-370 | Electrical installations in ships: Guidance on the selection of cables for telecommunication and data. |
DNV TAP 827.50/1 | Type Approval Program - Optical Fibre Cables |
ABS SVR | Rules for building and classing. Steel Vessels. |
ABS SMR | Rules for building and classing. Steel vessels under 90 meters. |
IEC 60793 | General specifications for both multimode and single-mode optical fibres |
IEC 60794 | general specifications for optical fibres cables |