Description
Store at: -40 to +70 °C
Install at: -40 to +50 °C, Bend minimum: 20 times O.D.
Operate at: -40 to +90 °C, Bend minimum: 10 times O.D.
Pull maximum: 150N
Design
Conductor : Solid or stranded bare copper 0.35mm2
Fire protection : fire resistant tape
Insulation : Polyolefin Ø 2.75mm
Pair : 2 insulated conductors stranded together into a pair
Colour code : 1.Green/red 2.Blue/brown
Assembling : No 1 pair with fillers or no 2 pairs stranded together into a compact core
Screen : Aluminium/polyester tape (100%) with tinned copper braid (coverage ≥60%)
Inner jacket : Black or purple Fire Retardant LSZH SHF1 material (Ø 8.6mm)
Armour : galvanized steel, tinned coppe or bronze wires braid (nominal coverage 85%)
Outer jacket : Black or purple Fire Retardant, LSZH and UV Resistant SHF2 material
Marking : APS Finland – ww/yy – ARMOURED FIRE RESISTANT PROFIBUS MARINE …x2x0.35mm2 LSZH SHF2 – IEC 60331-23 IEC60332-3-22 Cat.A – lot + meter
Environmental properties and Fire Performances
Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-1, IEC 61034-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : IEC 60331-23 (Max changes in Impedance and Attenuation @ 4-16MHz : ±25%)
Ozone resistant : IEC60811-2-1, DIN VDE 0472 part 805 B
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC 60811-404
UV resistant : ASTM-D-2565-99 (2008), 500 hours cycle 1, max change allowed in elongation after the test : 40%
Cold bend & impact : IEC 60092-350, CSA C22.2
Ordering and delivery information
Pair count | P/N | O.D [mm] | Weight [kg/km] | Packaging |
---|---|---|---|---|
1 pair (violet) | OPBX1P035F1x2 | 12.6 | 220 | 500 m (+/-5%) |
1 pair (black) | OPBX1P035F1x2B | 12.6 | 220 | 500 m (+/-5%) |
2 pairs (violet) | OPBX2P035F1x2 | 12.6 | 230 | 500 m (+/-5%) |
2 pairs (black) | OPBX2P035F1x2B | 12.6 | 230 | 500 m (+/-5%) |
x = “A” for Galvanized Steel wire braid, “T” for Tinned Copper wire braid, “B” for Bronze wire braid.
Electrical characteristics (IEC60092-350, IEC61784, IEC61158)
Operation voltage : 100V
Test voltage : 1000V d.c.
Resistance of the conductor @ 20°C : ≤ 55.0 Ω/km
Insulation resistance @ 20°C : ≥ 1GΩxkm
Nominal Capacitance @ 800Hz : 30 pF/m Characteristic impedance : 150 Ω ± 15 @ 1MHz
Nominal attenuation : | 45 dB/km | @ 16MHz |
22 dB/km | @ 4MHz | |
5 dB/km | @ 38,4 KHz | |
3 dB/km | @ 9,6 KHz | |
Baudrate : | 9.6 kBits/s | @ Max. 1200m |
19.2 kBits / | @ Max. 1200m | |
93.75 kBits/s | @ Max. 1200m | |
187.5 kBits /s | @ Max. 1000m | |
500 kBits /s | @ Max. 400m | |
1.5 MBits /s | @ Max. 200m | |
12 MBits /s | @ Max. 100m |
Other standards of reference
IEC 60092-370 | Electrical installations in ships: Guidance on the selection of cables for telecommunication and data. |
IEC 60092-360 | Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. |
DNV TAP 827.50/2 | Type Approval Program |
ABS SVR | Rules for building and classing. Steel Vessels. |
ABS SMR | Rules for building and classing. Steel vessels under 90 meters. |
IEC 60811 | Insulating and sheathing materials of electric cables - Test method |
Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.