MOG Profibus DP 1 &2 pairs stranded conductor 0.35mm2, SHF2

EMC screened, stranded conductor SHF2, Fire Retardant IEC60332-3-22 Cat.A
OPB_P035F2, 19.05.2014/AP rev.3
Type Approval: DNV-GL TAE00001S5

 

Print or Download PDF

Description

 

     

 

Store at: -40 to +70 °C
Install at: -40 to +50 °CBend minimum: 20 times O.D.
Operate at: -40 to +90 °CBend minimum: 10 times O.D.
Pull maximum: 100N

 

 

Design

Conductor : Stranded bare copper 7×0.25 (0.35mm2)
Insulation : Polyolefin Ø2.75mm
Pair : No 2 insulated conductors stranded together into a pair
Colour code : 1.Green/red 2.Blue/brown
Assembling : No 1 pair with fillers or no 2 pairs stranded together into a compact core
Screen : Aluminium/polyester tape (100%) with tinned copper braid (coverage ≥60%)
Outer jacket : Black or Purple Fire Retardant and UV Resistant SHF2 material, LSZH (Ø 8.6mm)
Marking : APS Finland – PROFIBUS MARINE …x2x0.35mm2 SHF2 – IEC60332-3-22 Cat.A – CE – lot + meter

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : YES – NES 713, CEI 20-37/7
Flame retardant : YES – IEC 60332-1-2
Fire retardant : YES – IEC 60332-3-22 Cat.A
Fire resistant : NO – IEC 60331-25
Ozone resistant : YES – DIN VDE 0472 part 805 B
Weather resistant : YES – ASTM G 154, EN 11507
LSZH SHF2 : YES – IEC 60092-359:1987-03
Oil resistant : YES (oil, fuels and hydrocarbons) – IEC60811
Water resistant : YES – IEC60502
UV resistant : YES – ASTM-D-2565-92A

 

 

Ordering and delivery information

Pair countP/NO.D [mm]Weight [kg/km]Packaging
1 pair (black)OPB1P035F28.695500 m (+/-5%)
1 pair (violet)OPB1P035F2V8.695500 m (+/-5%)
2 pairs (black)OPB2P035F28.6110500 m (+/-5%)
2 pairs (violet)OPB2P035F2V8.6110500 m (+/-5%)

 

 

Electrical characteristics (IEC60092-350, IEC61784, IEC61158)

Operation voltage : 100V
Test voltage : 1500V a.c. for 1 minute
Resistance of the conductor @ 20°C : ≤ 55.0Ω/km

Insulation resistance @ 20°C : ≥ 1GΩxkm
Nominal Capacitance @ 800Hz : 30 pF/m 
Characteristic impedance : 150 Ω ± 15 @ 1MHz

Nominal attenuation :45 dB/km@ 16MHz
22 dB/km@ 4MHz
5 dB/km@ 38,4 KHz
3 dB/km@ 9,6 KHz
Baudrate :9.6 kBits/s@ Max. 1200m
19.2 kBits /@ Max. 1200m
93.75 kBits/s@ Max. 1200m
187.5 kBits /s @ Max. 1000m
500 kBits /s@ Max. 400m
1.5 MBits /s@ Max. 200m
12 MBits /s@ Max. 100m

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2Type Approval Program
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
IEC 60811Insulating and sheathing materials of electric cables - Test method

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

 

 

 

 

 

 

SKU: OPB_P035F2 Categories: , ,