Standards of reference and applications
IEC 60092-370 | Electrical installations in ships: Guidance on cables for telecommunication and data. |
IEC 60092-360 | Electrical installations in ships: Insulating and sheating materials. |
DNV TAP 827.50/2 | Type Approval Program |
ABS SVR | Rules for building and classing. Steel Vessels. |
ABS SMR | Rules for building and classing. Steel vessels under 90 meters. |
CEI EN 50288-1 | Multi-element metallic used in analogue and digital communication and control. |
CEI EN 50288-2-1 | Setional specification for screened cables characterised up to 100MHz |
CEI EN 50289 | Communication cables - Specifications for test methods |
IEC 60811 | Insulating and sheathing materials of electric cables - Test method |
Standards | EIA/TIA 568-C.2, ISO/IEC 11801, UL444, UL1581, UL1666 |
Applications | 100Base-TX, 100Base-T, 100VG-AnyLAN, 1000Base-TX, ATM |
Type Approval
Pending
Installation Features
Store at -40 to +70 °C
Install at -40 to +60 °C
Operate at : -40 to +80 °C
Bend minimum : 10 times O.D.
Bend minimum : 10 times O.D.
Pull maximum : 40N
Design
Conductor : solid annealed copper AWG24
Insulation : polyethylene foam/skin, nominal diameter 1.20mm
Pair : 2 insulated conductors stranded together
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown
Screen 1 : aluminium/polyester or aluminium/polyester/aluminium tape over each single pair
Screen 2 : overall aluminium/polyester or aluminium/polyester/aluminium tape with overlap and drain wire
Outer jacket : grey Fire Retardant and UV Resistant SHF1 material, LSZH (nominal thickness 0.9mm)
Marking : APS Finland – ww/yy – F/FTP 4x2xAWG24 Category 5e – 100Ohm – LSZH SHF1 IEC60332-3-24 Cat.C – lot + m
Environmental properties and Fire Performances
Degree of acidity of gases : | IEC 60754-1, IEC 60754-2 (pH value >/= 4.3 and Conductivity < /=10uS/mm) |
Halogen acid gas : | IEC 60754-1, IEC 60754-2 (Halogen acid gas emission = 0.5%) |
Smoke Emission : | IEC 61034-2, EN 50268-2 (Transmittance >/= 60%) |
Toxicity of evolved gas : | EN 50305 9.2 |
Flame retardant : | IEC 60332-1-2 |
Fire retardant : | IEC 60332-3-24 Cat.C |
Oil resistant : | intermittent splash |
UV resistant : | IEC60811-2-1, ASTM-D-2565-92A |
Electrical characteristics
Frequency (MHz) : | 1 | 4 | 10 | 16 | 20 | 31.25 | 62.5 | 100 | 155 | 200 |
Attenuation (dB/100m) | 2.0 | 4.1 | 6.5 | 8.2 | 9.3 | 11.7 | 17.0 | 22.0 | 25.0 | 30.0 |
NEXT (dB) | 65.3 | 56.3 | 50.3 | 45.8 | 44.3 | 42.9 | 38.4 | 35.3 | 34.0 | 32.0 |
ELFEXT (dB) | 63.8 | 51.8 | 43.8 | 39.7 | 37.8 | 35.8 | 33.9 | 23.8 | 21.7 | 19.9 |
Return Loss | 20 | 23 | 25 | 25 | 25 | 23.6 | 21.5 | 20.1 | 19.0 | 18.0 |
ACR (dB/100m) | 78.1 | 71.3 | 64.4 | 60.8 | 57.1 | 49.7 | 41.6 | 31.8 | 25.1 | 17.8 |
Test voltage : | 700 Vrms (cond/cond and cond/screen) for 1 minute |
Conductor resistance : | = 88 Ohm/km @ 20°C |
Insulation resistance : | >/= 500 MOhmxkm |
Nominal Capacitance : | 52 pF/m (cond/cond) |
Characteristic impedance : | 100 +/- 5 Ohm @ 100MHz |
Capacitance unbalance : | Min. 160 pF/100m @ 1KHz (P-to-G) |
Ordering and delivery information
Pair count | P/N | O.D [mm] | Weight [kg/km] | Packaging |
4 pairs | O5EFF4P24S1 | 7.5 | 70.0 | drum 500m / 1000m (+/-5%) |
Recommended connectivity
Keystone jack : KJ6ASTPNH
RJ45 plug : P456SAPS
Panel : PPE24SU, OPPE24SU
Patchcords : PCMJ5ES_, PCMJ6S_
Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.