MUTX10G2 type, central loose tube, dielectric, LSZH SHF2 UVR, fire resistant

Up to 24 cores, dielectric armoured, SHF2, Fire Retardant & Resistant
MUTX10G2, 30.09.2021/AP rev.0/AP
Type Approval: –

 

 

Print or Download PDF

Description

 

   

 

Store at : -20 to +80 °C
Install at : -5 to +65 °C / pull maximum: 1000N / minimum bending radius : 20 times O.D.
Operate at : -20 to +80 °C / pull maximum: 500N / minimum bending radius: 10 times O.D.
Crush maximum : 2000 N/10 cm (< 0.15 dB/fiber after test)

 

Design

Bare fiber : 250µm
Buffer : Loose tube (PBT), jelly filled, natural or white colour 
Colour code : See table
Peripheral member :  swellable glass yarns
Wrapping :  glass tape
Outer sheath : LSZH thermoset compound, UV resistant (XLSZH – SHF2)

Marking :  APS Finland ww/mm – MUTX10G2 FIBER OPTIC CABLE [Fibre type] – LSZH SHF2 UVR – IEC60331-25 – IEC 60332-3-24 – Lot no + meter  

Environmental properties & fire performances

SHF2 : IEC 60092-360 (IEC 60092-359:1987-03)
Degree of acidity of gases :
IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)

Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Flame retardant :  IEC 60332-1-2
Fire retardant :  IEC 60332-3-24
Fire resistant :  IEC 60331-25
Water penetration : no water leakage in 24 h up to the sheath.

 

 

Colour code of fibers (EIA/TIA 598)

123456789101112
BlueOrangeGreenBrownGreyWhiteRed BlackYellow VioletPinkAqua
131415161718192021222324
Blue/b.Orange/b.Green/b.Brown/b.Grey/b.White/b.Red/b.NaturalYellow/b.Violet/b.Pink/b.Aqua/b.

 

 

Ordering and delivery information

Fiber countOuter diameter (mm)Weight (kg/km)P/NPackaging
27.060MUTX10G2 ff cdrum 2000m (+/-5%)
47.060MUTX10G2 ff cdrum 2000m (+/-5%)
87.060MUTX10G2 ff cdrum 2000m (+/-5%)
127.060MUTX10G2 ff cdrum 2000m (+/-5%)
168.0060MUTX10G2 ff cdrum 2000m (+/-5%)
248.0060MUTX10G2 ff cdrum 2000m (+/-5%)

ff =  S2 for G652D, A1 for G657A1, M1 for OM1, M2 for OM2, M3 for OM3, M4 for OM4, M5 for OM5.

c =  R for red, B for black, G for grey, L for blue, A for Aqua, V for violet, L for Lime, Y for yellow, R for Green.

 

Other standards of reference

IEC 60092-370Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.50/1Type Approval Program - Optical Fibre Cables
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
IEC 60793General specifications for both multimode and single-mode optical fibres
IEC 60794general specifications for optical fibres cables
Every effort has been put so that this document is most reliable and free from errors. However, APS Cables & Connectors Oy cannot be considered responsible for any mistake in this document and users should consult APS Cables & Connectors Oy for any information needed. APS Cables & Connectors Oy reserves the right to make changes to the documents at any time, without prior notice.