Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the wa_wcc_txt domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /var/www/vhosts/aps-finland.fi/httpdocs/wp-includes/functions.php on line 6121
MUT10G2 type, central loose tube, dielectric, LSZH SHF2 UVR, fire retardant IEC60332-3-24 - APS Finland

MUT10G2 type, central loose tube, dielectric, LSZH SHF2 UVR, fire retardant IEC60332-3-24

Up to 24 cores, dielectric armoured, SHF2, Fire Retardant
MUT10G2, 28.09.2021/AP rev.0/AP
Type Approval: –

 

 

Print or Download PDF

Description

 

   

 

Store at : -20 to +80 °C
Install at : -5 to +65 °C / pull maximum: 1000N / minimum bending radius : 20 times O.D.
Operate at : -20 to +80 °C / pull maximum: 500N / minimum bending radius: 10 times O.D.
Crush maximum : 2000 N/10 cm (< 0.15 dB/fiber after test)

 

Design

Bare fiber : 250µm
Buffer : Loose tube (PBT), jelly filled, natural or white colour 
Colour code : See table
Peripheral member :  swellable glass yarns
Wrapping :  swellable water blocking tape
Outer sheath : LSZH thermoset compound, UV resistant (XLSZH – SHF2)

Marking :  APS Finland ww/mm – MUT10G2 FIBER OPTIC CABLE [Fibre type] – LSZH SHF2 UVR – IEC 60332-3-24 – Lot no + meter  

Environmental properties and Fire Performances

SHF2 : IEC 60092-360 (IEC 60092-359:1987-03)
Degree of acidity of gases :
IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)

Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Flame retardant :  IEC 60332-1-2
Fire retardant :  IEC 60332-3-24
Water penetration : no water leakage in 24 h up to the sheath.

 

 

Colour code of fibers (EIA/TIA 598)

123456789101112
BlueOrangeGreenBrownGreyWhiteRed BlackYellow VioletPinkAqua
131415161718192021222324
Blue/b.Orange/b.Green/b.Brown/b.Grey/b.White/b.Red/b.NaturalYellow/b.Violet/b.Pink/b.Aqua/b.

 

 

Ordering and delivery information

Fiber countOuter diameter (mm)Weight (kg/km)P/NPackaging
26.2055MUT10G2 ff cdrum 2000m (+/-5%)
46.2055MUT10G2 ff cdrum 2000m (+/-5%)
86.2055MUT10G2 ff cdrum 2000m (+/-5%)
126.2055MUT10G2 ff cdrum 2000m (+/-5%)
168.0070MUT10G2 ff cdrum 2000m (+/-5%)
248.0070MUT10G2 ff cdrum 2000m (+/-5%)

ff =  S2 for G652D, A1 for G657A1, M1 for OM1, M2 for OM2, M3 for OM3, M4 for OM4, M5 for OM5.

c =  R for red, B for black, G for grey, L for blue, A for Aqua, V for violet, L for Lime, Y for yellow, R for Green.

 

Other standards of reference

IEC 60092-370Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.50/1Type Approval Program - Optical Fibre Cables
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
IEC 60793General specifications for both multimode and single-mode optical fibres
IEC 60794general specifications for optical fibres cables
Every effort has been put so that this document is most reliable and free from errors. However, APS Cables & Connectors Oy cannot be considered responsible for any mistake in this document and users should consult APS Cables & Connectors Oy for any information needed. APS Cables & Connectors Oy reserves the right to make changes to the documents at any time, without prior notice.