Description
Store at: -40 to +60 °C
Install at: -40 to +60 °C, Bend minimum: 5 times O.D.
Operate at: -40 to +60 °C, Bend minimum: 10 times O.D.
Pull maximum: 100N
Design
Conductor : solid bare copper AWG23/1
Insulation : Cellular polyolefin (SFS-PE), nominal Ø 1.38 mm
Pair : No 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown (IEC 708-1)
Screen 1 : Aluminium/polyester or Aluminium/polyester/aluminium tape over each single pair
Screen 2 : overall Tinned Copper Wire Braid
Outer jacket : Grey Fire Retardant and UV Resistant SHF1 material, LSZH
Marking : APS Finland – ww/yy – S/FTP 4x2xAWG23/1 Cat.7 LSZH SHF1 – IEC60332-3-22 Cat A – lot + m
Environmental properties and Fire Performances
Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Oil resistant : intermittent splash – permanent resistance available upon request
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Electrical characteristics (IEC 60811, EN 50288-4-2)
Test voltage : 0.7kV a.c. for 1 minute
Resistance of the conductor @ 20°C : ≤ 14,5 /100m
Insulation resistance : ≥ 500 MΩxkm (100V-500V)
Nominal Capacitance @ 800÷1000MHz : 45 pF/m
Average characteristic impedance : 100 ± 15 Ω @ 1-100MHz
Transfer impedance : ≤ 3mΩ/m @ 10MHz
Frequency (MHz) : | 1 | 4 | 10 | 16 | 20 | 31.25 | 62.5 | 100 | 155 | 200 | 300 | 400 | 500 | 600 | 900 | 1000 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Attenuation dB/100m (typical) | 1.7 | 3.2 | 5.2 | 6.5 | 7.3 | 9.4 | 13.6 | 17.0 | 22.2 | 24.3 | 30.2 | 35.2 | 39.1 | 43.5 | 55.2 | 58.1 |
NEXT dB (typical) | 105 | 105 | 105 | 105 | 105 | 105 | 103 | 100 | 98 | 95 | 93 | 90 | 87 | 85 | 81 | 80 |
ACR dB/100m | 103 | 102 | 100 | 98 | 98 | 96 | 89 | 83 | 76 | 71 | 73 | 55 | 48 | 41 | 26 | 22 |
ELFEXT dB/100m (typical) | 95 | 93 | 92 | 91 | 90 | 86 | 82 | 77 | 73 | 70 | 67 | 64 | 62 | 60 | 53 | 50 |
Return Loss dB (typical) | 25 | 28 | 30 | 30 | 30 | 30 | 30 | 30 | 28 | 26 | 25 | 24 | 23 | 23 | 21 | 20 |
Ordering and delivery information
Pair count | P/N | O.D [mm] | Weight [kg/km] | Packaging |
---|---|---|---|---|
4 pairs | O7SF4P23S1 | 8.1 | 80 | 500 m (+/-5%) |
Other standards of reference
IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units.
DNV TAP 827.50/2 Type Approval Program
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
CEI EN 50288-1 Multi-element metallic used in analogue and digital communication and control : Generic Specification
CEI EN 50288-2-1 Setional specification for screened cables characterised up to 100MHz
CEI EN 50288-5-1 Setional specification for screened cables characterised up to 250MHz
CEI EN 50288-4-2 Setional speci cation for screened cables characterised up to 600MHz
CEI EN 50289 series Communication cables - Specifications for test methods
IEC 60811 Insulating and sheathing materials of electric cables - Test method
Standards EIA/TIA 568-C.2, ISO/IEC 11801, UL444, UL1581, UL1666
Applications 100Base-TX, 100Base-T, 100VG-AnyLAN, 1000Base-TX, ATM
Every effort has been put so that this document is most reliable and free from errors. However, APS Cables & Connectors Oy cannot be considered responsible for any mistake in this document and users should consult APS Cables & Connectors Oy for any information needed. APS Cables & Connectors Oy reserves the right to make changes to the documents at any time, without prior notice.