Description
Store at : -0 to +50 °C
Install at : -10 to +50 °C, Bend minimum : 20 times O.D.
Operate at : -30 to +80 °C, Bend minimum : 15 times O.D.
Pull maximum : 100N
Design
Conductor : solid bare copper 0.575mm
Insulation : Cellular polyolefin Ø1.5mm
Pair : 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown (IEC 708-1)
Screen 1 : Aluminium/polyester or Aluminium/polyester/aluminium tape over each single pair
Screen 2 : tinned copper wire braid
Inner jacket : Grey Fire Retardant SHF1 material, LSZH (nominal Ø 8.3mm)
Armour : Galvanized steel, tinned copper or bronze wire braid. Coverage ≥80%.
Outer jacket : Grey RAL7035 Fire Retardant and UV Resistant SHF1 material, LSZH (nominal thickness 1.0mm)
Marking : APS Finland – ww/yy – ARMOURED S/FTP Flex 4x2xAWG23/1 Cat.6A SHF1 – IEC60332-3-22 Cat A – lot + m
Environmental properties and Fire Performances
Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Oil resistant : intermittent splash – permanent resistance available upon request
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Electrical characteristics (IEC 60811, EN 50288-4-2)
Test voltage : 0.7kV a.c. for 1 minute
Resistance of the conductor @ 20°C : ≤ 69,5 /km
Insulation resistance : ≥ 5GΩxkm
Nominal Capacitance @ 800÷1000MHz : 45 pF/m
Average characteristic impedance : 100 ± 15 Ω @ 100MHz Transfer impedance : ˂ 30 mΩ/m @ 10MHz
Frequency (MHz) : | 1 | 4 | 10 | 20 | 31,25 | 62,5 | 100 | 155 | 200 | 300 | 400 | 500 |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Attenuation dB/100m (nominal) | 1,9 | 3,5 | 5,6 | 7,9 | 9,8 | 14,2 | 17,8 | 22,1 | 25,1 | 31,0 | 36,4 | 41,8 |
NEXT dB (nominal) | 100 | 100 | 100 | 100 | 100 | 100 | 98 | 95 | 93 | 88 | 85 | 83 |
ACR dB/100m (nominal) | 98,1 | 96,5 | 94,4 | 92,1 | 90,2 | 85,8 | 80,2 | 72,9 | 67,9 | 57,0 | 48,6 | 41,2 |
ELFEXT dB (nominal) | 103 | 103 | 98 | 95 | 91 | 87 | 80 | 78 | 72 | 70 | 68 | 62 |
Return Loss dB (nominal) | 24 | 28 | 30 | 30 | 30 | 30 | 30 | 29 | 28 | 26 | 24 | 23 |
Ordering and delivery information
Pair count, Armour type | P/N | O.D [mm] | Weight [kg/km] | Packaging |
---|---|---|---|---|
4 pairs, GSWB | O6ASF4P23S1A1 | 11.4 | 140 | drum 500m (+/-5%) |
4 pairs TCWB | O6ASF4P23S1T1 | 11.4 | 135 | drum 500m (+/-5%) |
4 pairs, BWB | O6ASF4P23S1B1 | 11.4 | 150 | drum 500m (+/-5%) |
Recommended connectivity
Keystone jack : KJ6ASTPNH
RJ45 plug : P456SAPS
Panel : OPPE24SU, PPE24SU
Patchcords : PCMJ6S_
Other standards of reference
IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units.
DNV TAP 827.50/2 Type Approval Program
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
CEI EN 50288-1 Multi-element metallic used in analogue and digital communication and control : Generic Specification
CEI EN 50288-2-1 Setional specification for screened cables characterised up to 100MHz
CEI EN 50288-5-1 Setional specification for screened cables characterised up to 250MHz
CEI EN 50288-4-2 Setional speci cation for screened cables characterised up to 600MHz
CEI EN 50289 series Communication cables - Specifications for test methods
IEC 60811 Insulating and sheathing materials of electric cables - Test method
Standards EIA/TIA 568-C.2, ISO/IEC 11801, UL444, UL1581, UL1666
Applications 100Base-TX, 100Base-T, 100VG-AnyLAN, 1000Base-TX, ATM
Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.