Description
Store at : –40 to +70 °C
Install at : -40 to +70 °C, Bend minimum : 10 times O.D.
Operate at : -40 to +70 °C, Bend minimum : 10 times O.D.
Pull maximum : 60N
Cable weight : 70 kg/km
Design
Conductor : solid bare copper AWG23
Insulation : polyethylene
Pair : 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown
Assembling : no 4 pairs assembled together around a PE central cross
Screen : aluminium/mylar tape (coverage 100%) with tinned copper drain wire 0.50mm
Inner jacket : grey Fire Retardant SHF1 material (nominal Ø 7.2mm)
Outer jacket : grey or black Fire Retardant SHF1 UV-Resistant material (nominal Ø 8.6mm)
Marking : APS Finland – ww/yy – F/UTP 4x2xAWG23/1 Cat.6 SHF1 – IEC60332-3-22 Cat A – lot + meter
Environmental properties and Fire Performances
Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Oil resistant : intermittent splash – permanent resistance available upon request
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Electrical characteristics
Test voltage : 2500 V DC for 2 minutes
Resistance of the conductor @ 20°C : ≤ 68 Ω/km Insulation resistance : ≥ 5 GΩxkm
Nominal Capacitance : 52 pF/m (cond/cond)
Average characteristic impedance : 100 ± 5 Ω @ 100MHz
Frequency (MHz) : | 1 | 4 | 8 | 10 | 16 | 20 | 25 | 31.25 | 62,5 | 100 | 200 | 250 |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Return Loss | 20.0 | 23.0 | 24.5 | 25.0 | 25.0 | 25.0 | 24.3 | 23.6 | 21.5 | 20.1 | 18.0 | 17.3 |
Attenuation (dB/100m) | 2.2 | 4.0 | 5.5 | 6.2 | 7.8 | 8.7 | 9.7 | 10.9 | 15.6 | 20.0 | 29.2 | 33.0 |
NEXT (dB) | 74.3 | 66.3 | 61.8 | 60.3 | 57.2 | 55.8 | 54.3 | 52.9 | 48.4 | 45.3 | 40.8 | 39.3 |
PS-NEXT (dB) | 72.3 | 63.3 | 58.8 | 57.3 | 54.2 | 52.8 | 51.3 | 49.9 | 45.4 | 42.3 | 37.8 | 36.3 |
ELFEXT (dB/100m) | 67.8 | 56.0 | 49.9 | 48.0 | 43.9 | 42.0 | 40.0 | 38.1 | 32.1 | 28.0 | 22.0 | 20.0 |
PS-ELFEXT (dB/100m) | 64.8 | 53.0 | 46.9 | 45.0 | 40.9 | 39.0 | 37.0 | 35.1 | 29.1 | 25.0 | 19.0 | 17.0 |
Ordering and delivery information
Pair count | P/N | O.D [mm] | Weight [kg/km] | Packaging |
---|---|---|---|---|
4 pairs | O6UT4P23S1 | 8.1 | 70.0 | drum 500m / 1000m (+/-5%) |
Recommended connectivity
Keystone jack : MJ6UK, MJ6UKTC
RJ45 plug : P456UAPS
Panel : PPE24SU, OPPE24SU
Patchcords : PCMJ6U_
Other standards of reference
IEC 60092-370 | Electrical installations in ships: Guidance on the selection of cables for telecommunication and data. |
IEC 60092-360 | Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. |
DNV TAP 827.50/2 | Type Approval Program |
ABS SVR | Rules for building and classing. Steel Vessels. |
ABS SMR | Rules for building and classing. Steel vessels under 90 meters. |
CEI EN 50288-1 | Multi-element metallic used in analogue and digital communication and control : Generic Specification |
CEI EN 50288-2-1 | Setional specification for screened cables characterised up to 100MHz |
CEI EN 50288-5-1 | Setional specification for screened cables characterised up to 250MHz |
CEI EN 50288-4-2 | Setional speci cation for screened cables characterised up to 600MHz |
CEI EN 50289 series | Communication cables - Specifications for test methods |
IEC 60811 | Insulating and sheathing materials of electric cables - Test method |
Standards | EIA/TIA 568-C.2, ISO/IEC 11801, UL444, UL1581, UL1666 |
Applications | 100Base-TX, 100Base-T, 100VG-AnyLAN, 1000Base-TX, ATM |