Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the wa_wcc_txt domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /var/www/vhosts/aps-finland.fi/httpdocs/wp-includes/functions.php on line 6170
MOG Cat.6 F/UTP 4 pairs AWG23/1 SHF1 - APS Finland

MOG Cat.6 F/UTP 4 pairs AWG23/1 SHF1

Category 6A, U/FTP, Non-armored, SHF1, Fire retardant IEC60332-3-22 Cat.A
O6FT4P23S1, 01.06.2014/AP rev.1

Type Approval : pending

Print or Download PDF

Description

    

 

Store at : -40 to +70 °C
Install at : -40 to +70 °CBend minimum : 10 times O.D.
Operate at : -40 to +70 °CBend minimum : 10 times O.D.
Pull maximum : 60N
Cable weight : 95 kg/km

 

 

Design

Conductor : solid bare copper AWG23
Insulation : polyethylene
Pair : 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown
Assembling : no 4 pairs assembled together around a PE central cross
Screen : aluminium/mylar tape (coverage 100%) with tinned copper drain wire 0.50mm
Inner jacket : grey Fire Retardant SHF1 material (nominal Ø 7.2mm)
Outer jacket : grey or black Fire Retardant SHF1 UV-Resistant material (nominal Ø 8.6mm)
Marking : APS Finland – ww/yy – F/UTP 4x2xAWG23/1 Cat.6 SHF1 – IEC60332-3-22 Cat A – lot + meter

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Oil resistant : intermittent splash – permanent resistance available upon request
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

Electrical characteristics

Test voltage : 2500 V DC for 2 minutes
Resistance of the conductor @ 20°C : ≤ 70 Ω/km
Insulation resistance : ≥ 5 GΩxkm
Nominal Capacitance : 50 pF/m (cond/cond)
Average characteristic impedance : 100 ± 5 Ω @ 100MHz


Frequency (MHz) :1481016202531.2562,5100200250
Return Loss20.023.024.525.025.025.024.323.621.520.118.017.3
Attenuation (dB/100m)2.24.05.56.27.88.79.710.915.620.029.233.0
NEXT (dB)74.366.361.860.357.255.854.352.948.445.340.839.3
PS-NEXT (dB)72.363.358.857.354.252.851.349.945.442.337.836.3
ELFEXT (dB/100m)67.856.049.948.043.942.040.038.132.128.022.020.0
PS-ELFEXT (dB/100m)64.853.046.945.040.939.037.035.129.125.019.017.0

 

Ordering and delivery information

Pair countP/NO.D [mm]Weight [kg/km]Packaging
4 pairsO6FT4P23S18.695.0drum 500m / 1000m (+/-5%)

 

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2Type Approval Program
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
CEI EN 50288-1Multi-element metallic used in analogue and digital communication and control : Generic Specification
CEI EN 50288-2-1Setional specification for screened cables characterised up to 100MHz
CEI EN 50288-5-1Setional specification for screened cables characterised up to 250MHz
CEI EN 50288-4-2Setional speci cation for screened cables characterised up to 600MHz
CEI EN 50289 seriesCommunication cables - Specifications for test methods
IEC 60811Insulating and sheathing materials of electric cables - Test method
Standards EIA/TIA 568-C.2, ISO/IEC 11801, UL444, UL1581, UL1666
Applications 100Base-TX, 100Base-T, 100VG-AnyLAN, 1000Base-TX, ATM