MOG 75Ohm coaxial cable RG6AU SHF1 unarmoured and armoured

Non-armoured and armoured SHF1, Fire Retardant IEC60332-3-24 Cat.C
OC75R6_1, 22.05.2014/AP rev.2
Type Approval: DNV TAE0000374 

 

Print or Download PDF

Description

    

 

 

 

Store at: -20 to +60 °C
Install at: 0 to +50 °CBend minimum: 10/20 times O.D.
Operate at: -30 to +70 °CBend minimum: 5/15 times O.D.

Design

Conductor : copperweld Ø 0,72 ± 0.025 mm
Dielectric : low density polyethylene Ø 4.70 ± 0.20 mm
Screen 1 : aluminium/poleysther/aluminium tape (width 20mm)
Screen 2 : silvered copper braid (coverage 96%)
Screen 3 : plain copper braid (coverage 96%)
Outer jacket (inner jacket for armoured version): black Fire Retardant and UV Resistant SHF1 material, LSZH
Marking : APS Finland – ww/yy – RG6 MARINE SHF1 – 75 OHM – IEC60332-3-24 Cat.C – lot + meter

Armoured version is supplied with additional:
Armour : galvanized steel wire braid
Outer jacket : black Fire Retardant and UV Resistant SHF1 thermoplastic material, LSZH
Marking : APS Finland – ww/yy – RG6 MARINE SHF1 ARMOURED – 75 OHM – IEC60332-3-24 Cat.C – DNV – lot + meter

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : YES – IEC 60332-1-2
Fire retardant : YES – IEC 60332-3-22 Cat.A
Fire resistant : NO
Ozone resistant : NO
Weather resistant : NO
LSZH SHF2 : NO
Oil resistant : NO
MUD resistant : NO
Water resistant : NO
Water penetration : NO
UV resistant : YES – ASTM-D-2565-92A

 

 

Electrical characteristics (IEC60092-350, EN 50290-2-23, IEC61196-1-108)

Impedance : 75 ± 3 ᘯ Capacitance : 67 ± 3 pF/m
Velocity ratio : 66%
Inner conductor resistance @ 500V : 97 ± 3 Ω/km
Braid resistance @ 500V : 5 ± 3 Ω/km
Spark tension of the sheath : 6 kV


Attenuation

MHz51050100200300500600800100013501500175021502250250027503000
dB2.02.86.08.512.015.019.821.925.529.134.236.639.945.646.549.452.055.8
4

Return Loss (IEC61196-1-113)
MHz30 ÷ 300300 ÷ 600600 ÷ 10001000 ÷ 20002000 ÷ 3000
dB>28>20>19>16>15

Ordering and delivery information

TypeP/NO.D [mm]Weight [kg/km]Packaging
RG6AU Non-armouredOC75R6U18.5125.5500m or 1000m (+/-5%)
RG6AU GSWB armouredOC75R6A111.5229.4500m (+/-5%)
RG6AU TCWB armouredOC75R6T111.5208.5500m (+/-5%)
RG6AU BWB armouredOC75R6B111.5219.5500m (+/-5%)

 

Other standards of reference

IEC 60092-370Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.10/20Type Approval Program - coaxial cables
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
MIL-C-17General specification for radio frequency coaxial cables
IEC61196-1Coaxial communication cables
EN 50290-2-23Insulation materials for telecommunication cables

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

SKU: OC75R6_1 Categories: , ,