MOG 75Ohm coaxial cable RG11AU SHF MUD, NEK606 unarmoured and armoured

Non-armoured and armoured SHF MUD, NEK606, Fire Retardant IEC60332-3-24 Cat.C
OC75R11UU, 01.10.2018/AP rev.1
Type Approval: DNV TAE0000374

 

 

Print or Download PDF

Description

 

    

 

Store at: -20 to +60 °C
Install at: 0 to +50 °CBend minimum: 10/20 times O.D.
Operate at: -40 to +90 °CBend minimum: 5/15 times O.D

Design

Conductor : tinned copper 7×0,40mm
Dielectric : low density polyethylene Ø 7.25 ± 0.18 mm
Screen 1 : aluminium/poleysther/aluminium tape (width 29mm)
Screen 2 : bare copper braid (coverage 96%)
Screen 3 : N/A
Outer jacket (inner jacket for armoured version): black Fire Retardant and UV Resistant cross-linked SHF MUD material, LSZH
Marking : APS Finland – ww/yy – RG11 MARINE SHF MUD NEK606 – 75 OHM – IEC60332-3-24 Cat.C – DNV GL – lot + meter

Armoured version is supplied with additional:
Inner jacket : black Fire Retardant material, LSZH
Armour :
galvanized steel, tinned copper or bronze wire braid

Outer jacket : black Fire Retardant and UV Resistant cross-linked SHF MUD material, LSZH
Marking : APS Finland – ww/yy – ARMOURED RG11 MARINE SHF MUD NEK606 – 75 OHM – IEC60332-3-24 Cat.C – DNV GL – lot + meter

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24 Cat.C
Ozone resistant : IEC60811-2-1, DIN VDE 0472 part 805 B
Weather resistant : ASTM G 154, EN 11507
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC60811, IRM 903
MUD resistant : NEK606:2009, IEC60092-350
Water absorption : IEC60811-1-3
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

 

 

Electrical characteristics (IEC60092-350, EN 50290-2-23, IEC61196-1-108)

Impedance : 75 ± 3 ᘯ
Capacitance : 67 ± 3 pF/m
Velocity ratio : 66%
Inner conductor resistance @ 500V : 20.5  ± 1.5 Ω/km
Braid resistance @ 500V : 4.4 ± 1.5 Ω/km Spark tension of the sheath : 5.5 kV


Attenuation

MHz51050100200300500600800100013501500175021502250250027503000
dB1.42.05.07.210.513.017.119.022.425.530.432.535.640.941.644.146.550.1

Return Loss (IEC61196-1-113)
MHz30 ÷ 300300 ÷ 600600 ÷ 10001000 ÷ 20002000 ÷ 3000
dB>27>27>23>18>16

 

 

Ordering and delivery information

TypeP/NO.D [mm]Weight [kg/km]Packaging
RG11U MUD Non-armouredOC75R11UU11.8199500m or 1000m (+/-5%)
RG11U MUD GSWB armouredOC75R11AU14.2330500m (+/-5%)
RG11U MUD TCWB armouredOC75R11TU14.2315500m (+/-5%)
RG11U MUD BWB armouredOC75R11BU14.2320500m (+/-5%)

 

 

Other standards of reference

IEC 60092-370Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.10/20Type Approval Program - coaxial cables
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
MIL-C-17General specification for radio frequency coaxial cables
IEC61196-1Coaxial communication cables
EN 50290-2-23Insulation materials for telecommunication cables

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

 
SKU: OC75R11_U Categories: , ,