Description
Store at: -20 to +60 °C
Install at: 0 to +50 °C, Bend minimum: 10/20 times O.D. (unarmoured/armoured)
Operate at: -30 to +70 °C, Bend minimum: 5/15 times O.D. (unarmoured/armoured)
Design
Conductor : bare copper Ø 1.65 + carbon black PE
Dielectric : foam polyethylene + carbon black Ø 7.20 nom.
Screen 1 : aluminium/polyester tape
Screen 2 : tinned copper braid (coverage 91%)
Outer jacket (inner jacket for armoured version): black Fire Retardant and UV Resistant SHF1 material, LSZH
Marking : APS Finland – ww/yy – RG11 NAVY SHF1 – 75 OHM – IEC60332-3-24 Cat.C – DNV GL – lot + meter
Armoured version:
Inner jacket :black Fire Retardant and UV Resistant material, LSZH
Armour : galvanized steel, tinned copper or bronze wire braid
Outer jacket : black Fire Retardant and UV Resistant SHF1 thermoplastic material, LSZH
Marking : APS Finland – ww/yy – RG11 NAVY SHF1 ARMOURED – 75 OHM – IEC60332-3-24 Cat.C – DNV GL – lot + meter
Environmental properties and Fire Performances
Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24 Cat.C
SHF1 : IEC 60092-360
Oil resistant : intermittent splash – permanent resistance available upon request
Electrical characteristics (IEC60092-350, EN 50290-2-23, IEC61196-1-108)
Impedance : 75 ± 3 ᘯ
Capacitance : 53 ± 3 pF/m
Velocity ratio : 84%
Inner conductor resistance @ 500V : ≤ 8.2 Ω/km
Braid resistance @ 500V : ≤ 5.0 Ω/km
Spark tension of the sheath : 3 kV
Attenuation
MHz 5 10 50 100 200 500 800 1000 1500 2150 2500 2750 3000
dB 1.2 1.7 4.2 6.2 9.3 15.5 20.5 23.4 32.5 42.5 45.8 50.1 50.1
Return Loss (IEC61196-1-113)
MHz 30 ÷ 470 470 ÷ 860 860 ÷ 2400
dB >31 >28 >24
Ordering and delivery information
Type | P/N | O.D [mm] | Weight [kg/km] | Packaging |
---|---|---|---|---|
RG11 NAVY Non-armoured | OC75R11N1 | 10.8 | 130.0 | 500m or 1000m (+/-5%) |
RG11 NAVY GSWB armoured | OC75R11NA1 | 14.0 | 280.0 | 500m (+/-5%) |
RG11 NAVY TCWB armoured | OC75R11NT1 | 14.0 | 255.0 | 500m (+/-5%) |
RG11 NAVY BWB armoured | OC75R11NB1 | 14.0 | 270.0 | 500m (+/-5%) |
Other standards of reference
IEC 60092-370 | Electrical installations in ships: Guidance on the selection of cables for telecommunication and data. |
DNV TAP 827.10/20 | Type Approval Program - coaxial cables |
ABS SVR | Rules for building and classing. Steel Vessels. |
ABS SMR | Rules for building and classing. Steel vessels under 90 meters. |
MIL-C-17 | General specification for radio frequency coaxial cables |
IEC61196-1 | Coaxial communication cables |
EN 50290-2-23 | Insulation materials for telecommunication cables |
Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.