Description
Store at: -40 to +70 °C
Install at -10 to +50 °C Bend minimum: 15 times O.D.
Operate at -30 to +70 °C, Bend minimum 10 times O.D.
Crush maximum : 2000N/100mm
Impact maximum: 25J
Design
Conductor : stranded tinned copper 19×0.18mm
Dielectric : low density polyethylene Ø2.95 ± 0.10 mm
Screen 1 : aluminium/poleysther/aluminium tape (width 15mm)
Screen 2 : tinned copper braid (coverage 93%)
Outer jacket (inner jacket for armoured version): black Fire Retardant and UV Resistant SHF1 material, LSZH
Marking : APS Finland – ww/yy – RG58 MARINE SHF1 – 50 OHM – IEC60332-3-24 Cat C – lot + meter
Armoured version is supplied with additional:
Armour : galvanized steel wire braid (tinned copper wire and bronze wire braid available upon request)
Outer jacket : black Fire Retardant and UV Resistant SHF1 thermoplastic material, LSZH
Marking : APS Finland – ww/yy – RG58 MARINE SHF1 “ARMOUR TYPE” – 50 OHM – IEC60332-3-24 Cat C – lot + meter
Environmental properties and Fire Performances
Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10μS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : NES 713, CEI 20-37/7
Flame retardant : YES – IEC 60332-1-2
Fire retardant : YES – IEC 60332-3-22 Cat.A
Fire resistant : NO
Ozone resistant : NO – DIN VDE 0472 part 805 B
Weather resistant : YES – ASTM G 154, EN 11507
LSZH SHF2 : NO – IEC 60092-359:1987-03
Oil resistant : NO (oil, fuels and hydrocarbons) – IEC60811
MUD resistant : NO – NEK 606:2009
Water resistant : YES – IEC60502
Water penetration : YES – IEC 60794-1-2-F5-B (inner core only)
UV resistant : YES – ASTM-D-2565-92A
Electrical characteristics (IEC60092-350, EN 50290-2-23, IEC61196-1-108)
Impedance : 50 ± 3 Ω
Capacitance : 100 ± 9 pF/m
Velocity ratio : 66%
Inner conductor resistance @ 500V : 6 ± 1.5 Ω/km Braid resistance @ 500V : 4.4 ± 1.5 Ω/km
Spark tension of the sheath : 5.5 kV
Attenuation
MHz 5 10 50 100 200 300 500 600 800 1000 1350 1500 1750 2150 2250 2500 2750 3000
dB 3.3 4.3 9.9 13.5 19.2 24.0 31.9 35.5 41.6 47.5 57.1 60.8 67.1 77.0 78.8 85.7 88.9 90.7
Return Loss (IEC61196-1-113)
MHz 30 ÷ 300 300 ÷ 600 600 ÷ 1000 1000 ÷ 2000 2000 ÷ 3000
dB >28 >23 >20 >15 >15
Ordering and delivery information
Type | P/N | O.D [mm] | Weight [kg/km] | Packaging |
RG58 Non-armoured | OC50R58U1 | 5.0 | 41.0 | 500m or 1000m (+/-5%) |
RG58 GSWB armoured | OC50R58A1 | 10.0 | 115.0 | 500m (+/-5%) |
RG58 TCWB armoured | OC50R58T1 | 10.0 | 110.0 | 500m (+/-5%) |
RG58 BWB armoured | OC50R58B1 | 10.0 | 120.5 | 500m (+/-5%) |
Other standards of reference
IEC 60092-370 | Electrical installations in ships: Guidance on the selection of cables for telecommunication and data. |
DNV TAP 827.10/20 | Type Approval Program - coaxial cables |
ABS SVR | Rules for building and classing. Steel Vessels. |
ABS SMR | Rules for building and classing. Steel vessels under 90 meters. |
MIL-C-17 | General specification for radio frequency coaxial cables |
IEC61196-1 | Coaxial communication cables |
EN 50290-2-23 | Insulation materials for telecommunication cables |
Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.