MOG 50Ohm coaxial cable RG58CU SHF1 unarmoured and armoured

Non-armoured and armoured SHF1, Fire Retardant IEC60332-3-24 Cat.C
OC50R58_1, 22.05.2014/AP rev.3
Type Approval: DNV TAE0000375

Print or Download PDF

Description

 

    

 

Store at: -40 to +70 °C
Install at -10 to +50 °C Bend minimum:  15 times O.D.
Operate at -30 to +70 °C, Bend minimum 10 times O.D.
Crush maximum :  2000N/100mm
Impact maximum:
 25J

 

 

Design

Conductor : stranded tinned copper 19×0.18mm
Dielectric : low density polyethylene Ø2.95 ± 0.10 mm
Screen 1 : aluminium/poleysther/aluminium tape (width 15mm)
Screen 2 : tinned copper braid (coverage 93%) 
Outer jacket (inner jacket for armoured version):  black Fire Retardant and UV Resistant SHF1 material, LSZH 

Marking : APS Finland – ww/yy – RG58 MARINE SHF1 – 50 OHM – IEC60332-3-24 Cat C – lot + meter 

Armoured version is supplied with additional: 
Armour : galvanized steel wire braid (tinned copper wire and bronze wire braid available upon request) 
Outer jacket : black Fire Retardant and UV Resistant SHF1 thermoplastic material, LSZH 
Marking : APS Finland – ww/yy – RG58 MARINE SHF1 “ARMOUR TYPE” – 50 OHM – IEC60332-3-24 Cat C – lot + meter 

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10μS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : NES 713, CEI 20-37/7
Flame retardant : YES – IEC 60332-1-2
Fire retardant : YES – IEC 60332-3-22 Cat.A
Fire resistant : NO
Ozone resistant : NO – DIN VDE 0472 part 805 B
Weather resistant : YES – ASTM G 154, EN 11507
LSZH SHF2 : NO – IEC 60092-359:1987-03
Oil resistant : NO (oil, fuels and hydrocarbons) – IEC60811
MUD resistant : NO – NEK 606:2009
Water resistant : YES – IEC60502
Water penetration : YES – IEC 60794-1-2-F5-B (inner core only)
UV resistant : YES – ASTM-D-2565-92A

 

Electrical characteristics (IEC60092-350, EN 50290-2-23, IEC61196-1-108)

Impedance : 50 ± 3 Ω
Capacitance : 100 ± 9 pF/m
Velocity ratio : 66%
Inner conductor resistance @ 500V : 6 ± 1.5 Ω/km Braid resistance @ 500V : 4.4 ± 1.5 Ω/km
Spark tension of the sheath : 5.5 kV
Attenuation

  MHz 10 50 100 200 300 500 600 800 1000 1350 1500 1750 2150 2250 2500 2750 3000 
dB3.34.39.913.519.224.031.935.541.647.557.160.867.177.078.885.788.990.7

Return Loss (IEC61196-1-113)
MHz30 ÷ 300300 ÷ 600600 ÷ 10001000 ÷ 20002000 ÷ 3000
dB>28>23>20>15>15

 

Ordering and delivery information

TypeP/NO.D [mm]Weight [kg/km]Packaging
RG58 Non-armouredOC50R58U15.041.0500m or 1000m (+/-5%)
RG58 GSWB armouredOC50R58A110.0115.0500m (+/-5%)
RG58 TCWB armouredOC50R58T110.0110.0500m (+/-5%)
RG58 BWB armouredOC50R58B110.0120.5500m (+/-5%)

 

 

Other standards of reference

IEC 60092-370Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.10/20Type Approval Program - coaxial cables
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
MIL-C-17General specification for radio frequency coaxial cables
IEC61196-1Coaxial communication cables
EN 50290-2-23Insulation materials for telecommunication cables

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

 

 

 