Description
Store at: -30 to +60 °C
Install at -10 to +50 °C Bend minimum 5/10 times O.D.
Operate at -40 to +90 °C, Bend minimum 10/15 times O.D.
Design
Conductor : stranded bare copper 7×0.75mm
Dielectric : low density polyethylene Ø 7.25 ± 0.18 mm
Screen 1 : aluminium/poleysther/aluminium tape (width 29mm)
Screen 2 : bare copper braid (coverage 96%)
Outer jacket : black Fire Retardant and UV Resistant cross-linked SHF MUD material, LSZH
Marking : APS Finland – ww/yy – RG213 MARINE SHF MUD NEK606 – 50 OHM – IEC60332-3-24 Cat C – DNV GL – lot + meter
Armoured version
Inner jacket : black Fire Retardant material, LSZH
Armour : galvanized steel, tinned copper or bronze wire braid
Outer jacket : black Fire Retardant and UV Resistant cross-linked SHF MUD material, LSZH
Marking : APS Finland – ww/yy – ARMOURED RG213 MARINE SHF MUD NEK606 – 50 OHM – IEC60332-3-24 Cat C – DNV GL – lot + meter
Environmental properties and Fire Performances
Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24 Cat.C
Ozone resistant : IEC60811-2-1, DIN VDE 0472 part 805 B
Weather resistant : ASTM G 154, EN 11507
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC60811, IRM 903
MUD resistant : NEK606:2009, IEC60092-350
Water absorption : IEC60811-1-3
UV resistant : ASTM G 154 IEC 60068-2-5
Electrical characteristics (IEC60092-350, EN 50290-2-23, IEC61196-1-108)
Impedance : 50 ± 5 ᘯ
Capacitance : 100 ± 3 pF/m
Velocity ratio : 66%
Inner conductor resistance @ 500V : 6 ± 1.5 Ω/km
Braid resistance @ 500V : 4.4 ± 1.5 Ω/km
Spark tension of the sheath : 4.0kV
Attenuation
MHz 5 10 50 100 200 300 500 600 800 1000 1350 1500 1750 2150 2250 2500 2750 3000
dB 1.4 1.9 3.9 5.6 8.3 10.3 13.7 15.3 17.9 20.3 24.7 26.1 29.8 33.6 34.7 37.1 39.5 41.7
Return Loss (IEC61196-1-113)
MHz 30 ÷ 300 300 ÷ 600 600 ÷ 1000 1000 ÷ 2000 2000 ÷ 3000
dB >22 >22 >22 >22 >18
Ordering and delivery information
Type | P/N | O.D [mm] | Weight [kg/km] | Packaging |
---|---|---|---|---|
RG213U MUD Non-armoured | OC50R213UU | 11.3 | 187.5 | 500m or 1000m (+/-5%) |
RG213U MUD GSWB armoured | OC50R213AU | 14.7 | 343.6 | 500m (+/-5%) |
RG213U MUD TCWB-armoured | OC50R213TU | 14.7 | 330.5 | 500m (+/-5%) |
RG213U MUD BWB armoured | OC50R213BU | 14.7 | 340.6 | 500m (+/-5%) |
Other standards of reference
IEC 60092-370 | Electrical installations in ships: Guidance on the selection of cables for telecommunication and data. |
DNV TAP 827.10/20 | Type Approval Program - coaxial cables |
ABS SVR | Rules for building and classing. Steel Vessels. |
ABS SMR | Rules for building and classing. Steel vessels under 90 meters. |
MIL-C-17 | General specification for radio frequency coaxial cables |
IEC61196-1 | Coaxial communication cables |
EN 50290-2-23 | Insulation materials for telecommunication cables |
Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.