MOG 50 Ohm coaxial cable RF900 SHF1 unarmoured

Non-armoured SHF1, Fire Retardant IEC60332-3-22 Cat.A
OC50RF9001, 03.01.2020/AP rev.0
Type Approval: DNV-GL pending 
 

Print or Download PDF

Description

 

    

 

Store at: -20 to +60 °C
Install at: 0 to +50 °CBend minimum: 76.2mm
Operate at: -40 to +85 °CBend minimum: 76.2mm

 

 

Design

Inner conductor:    Bare Copper (BC) tube nom. 6.65 mm
Dielectric:                Foam PE nom. 17.27 mm
Outer conductor:    Aluminum tape nom. 17.42 mm
Overall braid:          Tinned copper nom. 18.59 mm
Outer sheath:          Fire Retardant LSZH SHF1 material 22.10 +/- 0.5 mm

Marking :       APS Finland – ww/yy – RF900 50OHM – DNV GL – <batch no.> – LSZH SHF1 IEC 60332-3-22 – <meter marking>

Environmental properties and Fire Performances

Degree of acidity of gases:  IEC 60754-1/2 (outer jacket)  
Halogen acid gas:  IEC 60754-1/2 (outer jacket)
Smoke Emission:  IEC 61034-1/2 
Flame retardant:  IEC 60332-1
Fire retardant:  IEC 60332-3-22 Cat.A
UV resistant:  UL 1581

 

 

Electrical characteristics 

Impedance : 50 ± 3 ᘯ
Capacitance : 76.6 pF/m (nominal)
Velocity ratio :  87%
Insulation resistance: >5000 MΩ.km
Inner conductor resistance: 1.77 Ω/km
Outer conductor resistance: 2.71 Ω/km

Attenuation

FrequencyMHz3050150220450900150018002000250030005800
TypicaldB/100ft0.300.370.680.801.211.752.302.502.552.602.725.23
MaxdB/100ft0.440.530.770.901.321.902.552.802.903.303,805.40

 

 

Ordering and delivery information

TypeP/NO.D [mm]Packaging
RF900 SHF1 BlackOC50RF900122.10 +/- 0.5500m (+/-5%)

 

 

Other standards of reference

IEC 60092-370Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.10/20Type Approval Program - coaxial cables
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
MIL-C-17General specification for radio frequency coaxial cables
IEC61196-1Coaxial communication cables
EN 50290-2-23Insulation materials for telecommunication cables

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

 

 

 

 

 

 

 

SKU: OC50RF9001 Categories: , ,