Description
Store at: -20 to +60 °C
Install at: 0 to +50 °C, Bend minimum: 75mm
Operate at: -40 to +85 °C, Bend minimum: 75mm
Design
Inner conductor: Copper Clad Aluminum (CCA) nom. 4.47 mm
Dielectric: Foam PE nom. 11.56 mm
Outer conductor: Bonded aluminum foil nom. 11.71 mm
Overall braid: Tinned copper nom. 12.50 mm
Outer sheath: Fire Retardant LSZH SHF1 material 14.99 +/- 0.5 mm
Marking : APS Finland – ww/yy – RF600 50OHM – DNV GL – <batch no.> – LSZH SHF1 IEC 60332-3-22 – <meter marking>
Environmental properties and Fire Performances
Degree of acidity of gases: IEC 60754-1/2 (outer jacket)
Halogen acid gas: IEC 60754-1/2 (outer jacket)
Smoke Emission: IEC 61034-1/2
Flame retardant: IEC 60332-1
Fire retardant: IEC 60332-3-22 Cat.A
UV resistant: UL 1581
Electrical characteristics
Impedance : 50 ± 3 ᘯ
Capacitance : 76.8 pF/m (nominal)
Velocity ratio : 87%
Insulation resistance: >5000 MΩ.km
Inner conductor resistance: 1.74 Ω/km
Outer conductor resistance: 5.74 Ω/km
Attenuation
Frequency MHz 30 50 150 220 450 900 1500 1800 2000 2500 3000 5800
Typical dB/100ft 0.49 0.55 1.02 1.20 1.84 2.68 3.56 3.96 4.17 4.78 5.34 7.30
Max dB/100ft 0.54 0.66 1.07 1.29 1.88 2.80 3.60 4.10 4.30 5.00 5.50 8.20
Ordering and delivery information
Type | P/N | O.D [mm] | Packaging |
---|---|---|---|
RF600 SHF1 Black | OC50RF6001 | 14.99 +/- 0.5 | 500m (+/-5%) |
Other standards of reference
IEC 60092-370 | Electrical installations in ships: Guidance on the selection of cables for telecommunication and data. |
DNV TAP 827.10/20 | Type Approval Program - coaxial cables |
ABS SVR | Rules for building and classing. Steel Vessels. |
ABS SMR | Rules for building and classing. Steel vessels under 90 meters. |
MIL-C-17 | General specification for radio frequency coaxial cables |
IEC61196-1 | Coaxial communication cables |
EN 50290-2-23 | Insulation materials for telecommunication cables |
Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.