Description
Store at : -40 to +70 °C
Install at : -10 to +50 °C, Bend minimum : 20 times O.D.
Operate at : -40 to +70 °C, Bend minimum : 20 times O.D.
Pull maximum : 3000N
Crush maximum : 3000N/100mm
Impact maximum : 10J
Cable weight : 368 kg/km
Design
Bare fiber : 250µm
Buffer : Loose tube filled with jelly, housing up to 12 fibers
Colour code : See table
Fire protection : A fire barrier is applied over every single tube housing fibers
Central member : FRP
Cable core : Loose tubes and fillers (when necessary) are stranded around the central member.
Inner sheath : Black LSZH material, fire retardant.
Armour : steel wire armour. Coverage ≥80%.
Outer jacket : Black LSZH material, fire retardant, anti-termite & anti-rodent.
Marking : APS Finland ww/mm – Fiber Optic Cable FRSMTAHA “fiber count and type” – LSZH ATAR IEC60332-3-24 Cat.C IEC60331-25 – lot + meter
Environmental properties and Fire Performances
Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24 Cat.C
Fire resistant : IEC 60331-25
Water penetration : IEC 60794-1-2-F5-B (tubes only)
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Ordering and delivery information
Fiber count | P/N | Overall diameter (nom.) | Packaging |
---|---|---|---|
2 | FRSMTAHA02 ff | 15.2 mm | drum 2000m (+/-5%) |
4 | FRSMTAHA04 ff | 15.2 mm | drum 2000m (+/-5%) |
8 | FRSMTAHA08 ff | 15.2 mm | drum 2000m (+/-5%) |
12 | FRSMTAHA12 ff | 15.2 mm | drum 2000m (+/-5%) |
24 | FRSMTAHA24 ff | 15.2 mm | drum 2000m (+/-5%) |
48 | FRSMTAHA48 ff | 15.2 mm | drum 2000m (+/-5%) |
72 | FRSMTAHA72 ff | 15.2 mm | drum 2000m (+/-5%) |
ff = S2 for G652D, A1 for G657A1, M1 for OM1, M2 for OM2, M3 for OM3, M4 for OM4, M5 for OM5. |
Colour code of fibers
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
---|---|---|---|---|---|---|---|---|---|---|---|
Blue | Orange | Green | Brown | Grey | White | Red | Black | Yellow | Violet | Pink | Aqua |
Colour code of tubes
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | Fillers |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Blue | Orange | Green | Brown | Grey | White | Red | Black | Yellow | Violet | Pink | Aqua | Black |
Other standards of reference
IEC 60092-370 | Electrical installations in ships: Guidance on the selection of cables for telecommunication and data. |
DNV TAP 827.50/1 | Type Approval Program - Optical Fibre Cables |
ABS SVR | Rules for building and classing. Steel Vessels. |
ABS SMR | Rules for building and classing. Steel vessels under 90 meters. |
IEC 60793 | General specifications for both multimode and single-mode optical fibres |
IEC 60794 | general specifications for optical fibres cables |