Description
Store at : -40 to +70 °C
Install at : -10 to +50 °C, Bend minimum : 20 times O.D.
Operate at : -40 to +70 °C, Bend minimum : 20 times O.D.
Pull maximum : 3000N
Crush maximum : 2000N/100mm
Impact maximum : 10J
Cable weight : 268 kg/km
Design
Bare fiber : 250µm
Buffer : Loose tube (typical Ø3.0mm) filled with jelly, housing up to 24 fibers
Colour code : See table
Fire protection : A fire barrier is applied over the tube
Peripheral members : anti-rodent, water blocking glass yarns
Inner sheath : Black LSZH material, fire retardant.
Armour : concentrically applied steel wire armour. Coverage ≥80%.
Outer jacket : Black LSZH material, fire retardant, MUD and oil resistant. Nominal outer diameter 14.0mm.
Marking : APS Finland ww/mm – Fiber Optic Cable FRSCTAU “fiber count and type” – LSZH MUD IEC60332-3-22 Cat.A IEC60331-25 – lot + meter
Environmental properties and Fire Performances
Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Ozone resistant : IEC60811-2-1, DIN VDE 0472 part 805 B
Weather resistant : ASTM G 154, EN 11507
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC60811, IRM 903
MUD resistant : NEK606:2009, IEC60092-350
Water absorption : IEC60811-1-3
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Cold bend & impact : CSA C22.2 (-40°C)
Onshore : SEIC Cable Specification 1000-S-40-68-S-3014-00 Rev 06 sections 5.2.2.2 and 5.7
Ordering and delivery information
Fiber count | P/N | Packaging |
---|---|---|
2 | FRSCTAU02 ff | drum 2000m (+/-5%) |
4 | FRSCTAU04 ff | drum 2000m (+/-5%) |
8 | FRSCTAU08 ff | drum 2000m (+/-5%) |
12 | FRSCTAU12 ff | drum 2000m (+/-5%) |
16 | FRSCTAU16 ff | drum 2000m (+/-5%) |
24 | FRSCTAU24 ff | drum 2000m (+/-5%) |
ff = S2 for G652D, A1 for G657A1, M1 for OM1, M2 for OM2, M3 for OM3, M4 for OM4, M5 for OM5. |
---|
Colour code of fibers
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
Blue | Orange | Green | Brown | Grey | White | Red | Black | Yellow | Violet | Pink | Aqua |
13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 |
Blue/b. | Orange/b. | Green/b. | Brown/b. | Grey/b. | White/b. | Red/b. | Natural | Yellow/b. | Violet/b. | Pink/b. | Aqua/b. |
Colour code of tubes
Natural
Other standards of reference
IEC 60092-370 | Electrical installations in ships: Guidance on the selection of cables for telecommunication and data. |
IEC 60793 | General specifications for both multimode and single-mode optical fibres |
IEC 60794 | general specifications for optical fibres cables |