Description
Store at : -40 to +70 °C
Install at : -10 to +50 °C, Bend minimum : 20 times O.D.
Operate at : -40 to +90 °C, Bend minimum : 20 times O.D.
Pull maximum : 1500N
Crush maximum : 2000N/100mm
Impact maximum : 5J
Cable weight : 268 kg/km
Design
Bare fiber : 250µm
Buffer : Loose tube (typical Ø3.0mm) filled with jelly, housing up to 24 fibers
Colour code : See table
Peripheral members : anti-rodent glass yarns
Inner sheath : Black LSZH SHF1 material, fire retardant.
Armour : double layer of helically applied steel tape, with overlap. Optical coverage100%.
Outer jacket : Black LSZH cross-linked material SHF2, UVR, fire retardant (nominal thickness 1.8mm).
Marking : APS Finland – ww/mm – Fiber Optic Cable CTG1N215 “fiber count and type” – LSZH SHF2 IEC60332-3-22 Cat.A – lot + meter
Environmental properties and fire performances
SHF2 : IEC 60092-360 (IEC 60092-359:1987-03)
Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : NES 713, CEI 20-37/7
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Ozone resistant : DIN VDE 0472 part 805 B
Oil resistant : IEC60811
Water absorption : IEC60502
Water penetration : IEC 60794-1-2-F5-B
UV resistant : ASTM G 154 IEC 60068-2-5
Ordering and delivery information
Fiber count | P/N | Packaging |
---|---|---|
2 | CTG1N21502 ff | drum 2000m (+/-5%) |
4 | CTG1N21504 ff | drum 2000m (+/-5%) |
8 | CTG1N21508 ff | drum 2000m (+/-5%) |
12 | CTG1N21512 ff | drum 2000m (+/-5%) |
16 | CTG1N21516 ff | drum 2000m (+/-5%) |
24 | CTG1N21524 ff | drum 2000m (+/-5%) |
ff = S2 for G652D, A1 for G657A1, M1 for OM1, M2 for OM2, M3 for OM3, M4 for OM4, M5 for OM5. |
Colour code of fibers
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
Blue | Orange | Green | Brown | Grey | White | Red | Black | Yellow | Violet | Pink | Aqua |
13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 |
Blue/b. | Orange/b. | Green/b. | Brown/b. | Grey/b. | White/b. | Red/b. | Natural | Yellow/b. | Violet/b. | Pink/b. | Aqua/b. |
Colour code of tubes
Natural
Other standards of reference
IEC 60092-370 | Electrical installations in ships: Guidance on the selection of cables for telecommunication and data. |
IEC 60793 | General specifications for both multimode and single-mode optical fibres |
IEC 60794 | general specifications for optical fibres cables |