MOG DeviceNet Thick, Data + Power, SHF1

EMC screened, stranded conductor SHF1, Fire Retardant IEC60332-3-24 Cat.C
ODNT2DPS1, 06.08.2016/AP rev.00
Type Approval: 

 

Print or Download PDF

Description

    

 

Store at : -30 to +60 °C
Install at : -10 to +50 °CBend minimum: -40 to +80 °C 8 x O.D.
Operate at : -40 to +80 °CBend minimum : 15 x O.D.
Pull maximum : 100N

 

Design

 

Data Pair 1.3/3.8 (AWG15)
Conductor : stranded tinned copper wire, 19×0.25mm, nom. Ø 1.3mm
Insulation : PE, nom. Ø 3.8mm (colour code Blue/White)
Screen : Alu/PE laminated foil


Power Pair 1.7/2.7 (AWG18)
Conductor : stranded tinned copper wire, 19×0.25mm, nom. Ø 1.3mm
Insulation : PE, nom. Ø 3.8mm (colour code Red/Black)
Screen : Alu/PE laminated foil


Assembling : Data and power pair stranded together into a compact core, with fillers if necessary
Shield : Tinned copper wire braid (coverage 70%) with stranded copper drain wire.
Outer jacket : Fire Retardant, LSZH material SHF1. Colour according to customer’s request

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Toxicity of evolved gas : EN50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24 Cat.C

 

Ordering and delivery information

Pair countP/NO.D [mm]Weight [kg/km]Packaging
1 + 1 pairsODNT2DPS112.2100500 m (+/-5%)

 

Electrical characteristics (IEC60092-350, IEC61784, IEC61158)

Max operating voltage: 300 V
Test voltage: 1500V a.c. for 1 minute (wire/wire/screen)
Conductor resistance: ≤ 22.6 Ω/km (Data)
                                       ≤ 11.7 Ω/km (Power)
Insulation resistance: ≥ 200MOhm*km
Nominal capacitance (wire/wire): 39 pF/m @ 800Hz @ 1 KHz
Characteristic impedance: 120 Ω ± 10% @ 1 MHz
Capacity unbalanced to ground: ≤ 3937 pF/0km

Typical attenuation
125 MHz      0.42 dB/100m 

500 MHz      0.81 dB/100m 
1000 MHz    1.31 dB/100m

 

 

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2Type Approval Program
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
IEC 60811Insulating and sheathing materials of electric cables - Test method

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

 

 

 