Description
Store at : -30 to +60 °C
Install at : -10 to +50 °C, Bend minimum: -40 to +80 °C 8 x O.D.
Operate at : -40 to +80 °C, Bend minimum : 15 x O.D.
Pull maximum : 100N
Design
Data Pair 1.3/3.8 (AWG15)
Conductor : stranded tinned copper wire, 19×0.25mm, nom. Ø 1.3mm
Insulation : PE, nom. Ø 3.8mm (colour code Blue/White)
Screen : Alu/PE laminated foil
Power Pair 1.7/2.7 (AWG18)
Conductor : stranded tinned copper wire, 19×0.25mm, nom. Ø 1.3mm
Insulation : PE, nom. Ø 3.8mm (colour code Red/Black)
Screen : Alu/PE laminated foil
Assembling : Data and power pair stranded together into a compact core, with fillers if necessary
Shield : Tinned copper wire braid (coverage 70%) with stranded copper drain wire.
Outer jacket : Fire Retardant, LSZH material SHF1. Colour according to customer’s request
Environmental properties and Fire Performances
Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Toxicity of evolved gas : EN50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24 Cat.C
Ordering and delivery information
Pair count | P/N | O.D [mm] | Weight [kg/km] | Packaging |
---|---|---|---|---|
1 + 1 pairs | ODNT2DPS1 | 12.2 | 100 | 500 m (+/-5%) |
Electrical characteristics (IEC60092-350, IEC61784, IEC61158)
Max operating voltage: 300 V
Test voltage: 1500V a.c. for 1 minute (wire/wire/screen)
Conductor resistance: ≤ 22.6 Ω/km (Data)
≤ 11.7 Ω/km (Power)
Insulation resistance: ≥ 200MOhm*km
Nominal capacitance (wire/wire): 39 pF/m @ 800Hz @ 1 KHz
Characteristic impedance: 120 Ω ± 10% @ 1 MHz
Capacity unbalanced to ground: ≤ 3937 pF/0km
Typical attenuation
125 MHz 0.42 dB/100m
500 MHz 0.81 dB/100m
1000 MHz 1.31 dB/100m
Other standards of reference
IEC 60092-370 | Electrical installations in ships: Guidance on the selection of cables for telecommunication and data. |
IEC 60092-360 | Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. |
DNV TAP 827.50/2 | Type Approval Program |
ABS SVR | Rules for building and classing. Steel Vessels. |
ABS SMR | Rules for building and classing. Steel vessels under 90 meters. |
IEC 60811 | Insulating and sheathing materials of electric cables - Test method |
Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.