Description
Store at: -0 to +50 °C
Install at: 0 to +50 °C, Bend minimum: single 5xO.D., repeated 10xO.D.
Operate at: -30 to +70 °C, Bend minimum: single 5xO.D., repeated 10xO.D.
Design
Coaxial (1x)
Conductor : copperweld Ø 0.58 mm
Dielectric : low density polyethylene nominal Ø 3,70±0,10 mm
Braid : plain copper 168×0.10 mm, coverage 92%
Sheath 1 : flame retardant LSZH ø 6,20 ± 0,10 mm, black RAL9004
Electrical wires (2x)
Conductor: plain copper 2×0,75 mm2
Insulation: flame retardant LSZH ø 2,00 ± 0,10 mm, color: red and black
Outer sheath : flame retardant LSZH ø 10,00 ± 0,30 mm, UVR, black RAL9004
Marking : APS Finland – APSZH059H2 – RG59 + 2×0,75mm2 – LSZH UVR +70 °C – 300V – EN 50575:2014 + A1:2016 Eca – Lot no – WW/YY – xxx m
Environmental properties and Fire Performances
CPR Class: Eca
DoP: APSZH059H2-001
Degree of acidity of gases : IEC 60754-1, IEC 60754-2
Halogen acid gas : IEC 60754-1, IEC 60754-2
Smoke Emission : IEC 61034-2
Flame retardant : IEC 60332-1-1, IEC60332-2-1
Electrical characteristics
Coaxial
Impedance : 75ᘯ ± 3 nominal
Capacitance : 67pF/m nominal
Velocity ratio : 66%
Resistance of inner conductor: 154 Ohm/km
Resistance of outer conductor: 13 Ohm/km
Attenuation (typical)
MHz 5 10 50 100 300 600 1000 2150 3000
dB 2.3 3.1 7.4 10.7 19.4 28.7 38.0 60.9 72.7
Structural return loss
MHz 30-300 300-600 600-1000 1000-2000 2000-3000
dB >31 >28 >24 >18 >14
Screening effectiveness
MHz 100-900 900-2000 2000-3000
dB >57 - -
Electrical wires
Cores resistance: 26 Ohm/km
Operating voltage: 300 Vca
Testing voltage: 2000 Vca
Ordering and delivery information
Type | P/N | O.D [mm] | Weight [kg/km] | Retail Packaging |
---|---|---|---|---|
RG59 + 2x0.75 LSZH | APSZH059H21 | 10.00±0.30 mm | 109.70 | 100 m |
RG59 + 2x0.75 LSZH | APSZH059H22 | 10.00±0.30 mm | 109.70 | 200 m |
RG59 + 2x0.75 LSZH | APSZH059H25 | 10.00±0.30 mm | 109.70 | 500 m |
Every effort has been put so that this document is most reliable and free from errors. However, APS Cables & Connectors Oy cannot be considered responsible for any mistake in this document and users should consult APS Cables & Connectors Oy for any information needed. APS Cables & Connectors Oy reserves the right to make changes to the documents at any time, without prior notice.