Standards of reference
IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units.
CEI EN 50289 Communication cables - Specifications for test methods
EN 50290-2-23 Insulation materials for telecommunication cables
IEC 60811 Insulating and sheathing materials of electric cables - Test method
IEC 60793 General specifications for both multimode and single-mode optical fibres
IEC 60794 General specifications for optical fibre cables
Installation Features
Store at -10 to +70 °C
Install at -5 to +50 °C, bend minimum 15 times O.D.
Operate at : -20 to +70 °C, bend minimum : 20 times O.D.
Pull maximum : 80N
Design
S/FTP Category 6A
Conductor Bare copper stranded wires 23 AWG
Insulation PE
Core identification Blue – white, Orange – white, Green – white, Brown – white
Pairing Cores twisted to pairs with different lay lengths
Screen (individual) Aluminium foil on each pair
Stranding 4 screened pairs stranded together
Screen (overall) CuTn wire braid with copper drain wire
Jacket LSZH material, fire retardant
Power 3×2.5 mm2
Conductor Bare copper stranded wire Cl.2 or Cl.5
Insulation XLPE
Core identification 1. Blue, Brown, Grey or 2. Blue, Brown, Green/Yellow
Operating voltage 0.6/1 kV
Test voltage 2.0 kV AC
Insulation resistance ≥ 1GΩ x km
Conductor resistance ≤ 7.98 Ω/km
Signal Cable 1x2x24AWG
Conductor Tinned stranded copper 7×0,20 mm
Insulation PE nominal OD. 1,20 mm
Core identification White-Blue
Pairing/Stranding Cores twisted to form a pairs, Pairs stranded together, PES wrapped
Shielding Aluminium Foil + 7×0,20 mm Tinned copper drain wire
Sheath thickness nom. 0,60 mm
Sheath Grey LSZH 5,0 mm
Test voltage 1.0kV AC
Insulation resistance min. 1000 Mohm.km
Conductor resistance max 96.0 Ohm/km
Assembling (Non-armoured version)
Stranding (Lay-up) : DATA + SIGNAL + POWER stranded together, PES wrapped (separator)
Outer sheath : LSZH material, fire retardant (nominal thickness 1,00 mm)
Marking : APS Finland – ww/yy – CCTV COMPOSITE CABLE – Category 6A S/FTP 4P + 1x2xAWG24 + POWER 3×2.5 (3G2.5) – P/N – LSZH IEC60502 IEC60332-3 – lot + m
Assembling (Armoured version)
Stranding (Lay-up) : DATA + SIGNAL + POWER stranded together, PES wrapped (separator)
Inner sheath : LSZH material, fire retardant (nominal thickness 1,00 mm)
Armour : Galvanized Steel Wire braid
Outer sheath : LSZH material, fire retardant (nominal thickness 1,50 mm)
Marking : APS Finland – ww/yy – ARMOURED CCTV COMPOSITE CABLE – Category 6A S/FTP 4P + 1x2xAWG24 + POWER 3×2.5 (3G2.5) – P/N – LSZH IEC60502 IEC60332-3 – lot + m
Environmental properties
Halogen amount/acidity tests | IEC 60754-1/2 |
Smoke density test | IEC 61034-2 |
Flame retardant | IEC 60332-1 |
Fire ratardant | IEC 60332-3 |
Ordering and delivery information
Type | P/N | Nominal O.D. Inner jacket | Nominal O.D. Outer jacket | Packaging |
---|---|---|---|---|
S/FTP Cat.6A + 1P + 3x2.5 (non-armoured) | OC6ASF1P4325H | - | 15.0 | drum 500m (+/-5%) |
S/FTP Cat.6A + 1P + 3G2.5 (non-armoured) | OC6ASF1P43G25H | - | 15.0 | drum 500m (+/-5%) |
S/FTP Cat.6A + 1P + 3x2.5 (armoured) | OC6ASF1P4325GH | 15.0 | 19.0 | drum 500m (+/-5%) |
S/FTP Cat.6A + 1P + 3G2.5 (armoured) | OC6ASF1P43G25GH | 15.0 | 19.0 | drum 500m (+/-5%) |
Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.