Description
Standards of reference
EIA-TIA 568-B-2; ISO/IEC 11801; IEC 61156-5; EN 50173; EN 50288 (for Data Cat.6A)
IEC 60502-1 (for Power, insulation, armour & sheaths)
Installation Features
Store at -5 to +65 °C
Install at -5 to +65 °C, bend minimum 20 times O.D.
Operate at : -20 to +80 °C, bend minimum 20 times O.D.
Pull maximum : 350N
Design
- Category 6A, 4 pairsConductor : plain annealed copper wire, solid, AWG 23/1
Insulation : polyethylene
Colour code : white/blue, white/orange, white/green, white/brown.
Pair screen : Al/PET on each pair, 100% coverage
Overall screen : collective Al/PET, 100% coverage with tinned copper drain wire
Sheath : thermoplastic compound, LSZH, nominal Ø 7.5mmMax conductor resistance @ 20°C : 73 Ω/km
Min. insulation resistance @ 20°C : 1000 MΩ x km
Core/core capacitance : nom. 43 nF/km
Characteristic impedance : 100 ± 20 Ohm
Velocity of propagation : 77%
- Power 3 conductors 2.5mm²
Conductor : plain annealed copper wire, Class 2
Insulation : XLPE, colour coded (1.Brown, 2.Black, 3.Grey)
Max conductor resistance @ 20°C : 7.41 Ω/km
Min. insulation resistance @ 20°C : 1000 MΩ x km
Operating Voltage : 600/1000V
Dielectric test (core/core) : 3500 VAC 5 min.
- Assembling
Cable core : 1 Category 6A element and 3 power conductors stranded together into a compact core, with fillers and wrapping where necessary.
Inner jacket : LSZH thermoplastic compound, black colour
Armour : Galvanized Steel Wire Braid, coverage ≥ 80%
Outer jacket : LSZH thermoplastic compound, Ø 19.4mm, black colour
Marking : APS Finland – ww/yy – CCTV COMPOSITE CABLE DATA Category 6A F/FTP 4P AWG23/1 + POWER 3×2.5mm² – P/N – LSZH IEC60502 IEC60332-3-24 – lot + m
Environmental properties and Fire Performances
Degree of acidity of gases : IEC 60754-1, IEC 60754-2
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance ≥ 60%)
Toxicity of evolved gas : EN50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24
Ordering and delivery information
Cable type | P/N | O.D [mm] | Weight [kg/km] | Packaging |
---|---|---|---|---|
Unarmoured | OC6A4PFF325H | 14.7 | 390 | drum 500m (+/-5%) |
Armoured GSWB | OC6A4PFF325FH | 19.4 | 535 | drum 500m (+/-5%) |
Armoured GSWA | OC6A4PFF325AH | 19.4 | 543 | drum 500m (+/-5%) |
Armoured Bronze braid | OC6A4PFF325BH | 19.4 | 500 | drum 500m (+/-5%) |
Armoured St. Steel braid | OC6A4PFF325SH | 19.4 | 570 | drum 500m (+/-5%) |
Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.