CCTV Composite cable Fire Retardant 4xFO, 2 Pairs AWG24, 3×2.5mm2, LSZH, fire retardant, MUD resistant

4 optical fibres, 2 pairs AWG24, 3×2.5mm², LSZH, Fire Retardant IEC60332-3-22, MUD resistant, metallic armoured.
OC4S22P24325U Rev.00, Date 2021-04-05

 

Print or Download PDF

Description

      

Standards of reference

IEC 60092-370Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units.
CEI EN 50289 Communication cables - Specifications for test methods
EN 50290-2-23 Insulation materials for telecommunication cables
IEC 60811 Insulating and sheathing materials of electric cables - Test method
IEC 60793General specifications for both multimode and single-mode optical fibres
IEC 60794General specifications for optical fibre cables

 

 

Installation Features

Store at  -10 to +70 °C
Install at  -10 to +50 °C, bend minimum 20 times O.D.
Operate at : -40 to +90 °C, bend minimum : 20 times O.D.
Pull maximum : 1000N (unarmored), 3000N (armoured)

 

Design

Fiber Optic, 4 cores
Fiber: 125/250μm SM or MM (see Fiber Characteristics datasheets)
Buffer: PBTP tube nominal diam 1.8mm filled with jelly
Colour code: 1.Natural  2.Red  3.Green  4.Yellow
Protection: Glass yarns (alternatively aramide yarns)
Jacket: LSZH Orange, nominal thickness 0.7mm, nominal outer Ø 3.5mm 

Signal 2 pairs AWG24
Conductor
:  stranded tinned copper AWG24/7 strands

Insulation :  polyethylene nominal Ø 1.25
Assembling : no 2 insulated conductors colour coded (1.White, 2.Black) stranded together into a pair.
Screen : aluminium/polyester tape 100% coverage with tinned copper drain wire AWG24/7
Sheath : non-corrosive thermoplastic compound, LSZH, nom. Ø 3.5mm, colour coded (1.Grey, 2.Black)
Resistance of conductor @ 20°C :  ≤ 90 Ω/km
Insulation resistance @ 20°C :  
≥ 1000 MΩ x km 
Test Voltage :  
1000 V DC x 1 minute

Power 3 conductors 2.5mm²
Conductor :  stranded tinned copper 2.5mm2
Insulation :  XLPE, nominal Ø 3.5mm, colour coded (1.Blue, 2.Brown, 3.Green/Yellow)
Conductor resistance @ 20°C :  ≤ 8.21 Ω/km
insulation resistance @ 20°C :  ≥ 250 MΩ x km
Test Voltage :  2000V AC x 1 minute
Operating Voltage :  300/500V 

Assembling
Cable core : optical fiber, signal and power elements stranded together into a compact core, with fillers and wrapping where necessary.

Jacket :  MUD resistant LSZH compound, Ø 13.0mm, black colour 
Marking : APS Finland – ww/yy  –  CCTV COMPOSITE CABLE 4x “fiber type” + 2 PR AWG24 + 3×2.5mm²  –  MUD-RESISTANT LSZH IEC60332-3-22  –  P/N  –  lot + m 

 

 

Armoured version  
     Armour : galvanized steel wire or tinned copper wire or bronze braid or stainless steel concentric wires (cov. ≥85%). 
     Outer jacket : MUD resistant, LSZH compound, black colour (other colours available upon request)
     Marking : APS Finland – ww/yy – ARMOURED CCTV COMPOSITE CABLE 4x “fiber type” + 2 PR AWG24 + 3×2.5mm²  –  MUD-RESISTANT LSZH IEC60332-3-22  –  P/N  –  lot + m 

 

Environmental properties and Fire Performances

Degree of acidity of gases :  IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10μS/mm)
Halogen acid gas :  IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission :  IEC 61034-1/2 (Transmittance) ≥ 60%)
Toxicity of evolved gas :  EN50305 9.2
Flame retardant :  IEC 60332-1-2
Fire retardant :  IEC 60332-3-22
Ozone resistant : IEC60811-403
Weather resistant : ASTM G 154, EN 11507
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC60811, IRM 903
MUD resistant : NEK606:2009, IEC60092-350
Water absorption : IEC60811-1-3
UV resistant : ASTM-D-2565-16
 

 

Ordering and delivery information

Cable typeP/NO.D [mm]Weight [kg/km]Packaging
UnarmouredOC4S22P24325U 13.0310drum 500m (+/-5%)
Armoured GSWBOC4S22P24325HFU17.0420drum 500m (+/-5%)
Armoured TCWBOC4S22P24325HTU17.0420drum 500m (+/-5%)
Armoured GSWAOC4S22P24325HAU17.0490drum 500m (+/-5%)
Armoured Bronze braidOC4S22P24325HBU17.0420drum 500m (+/-5%)
Armoured St. Steel wiresOC4S22P24325HSU22.0850drum 500m (+/-5%)

XX =  fiber type = OS2=S2, OM1=M1, OM2=M2, OM3=M3, OM4=M4, OM5=M5.

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

SKU: OC4S22P24325U Categories: , ,