CCTV Composite cable Fire Resistant 4xFO, Power 3×2.5mm2, SHF1, Armoured TCWB

4 FO, 3×2.5mmsq, SHF1, Armoured TCWB, IEC60331, IEC60332-3-22 Cat.A.
OCX3254xxHoo1 Rev.00, Date 2019-04-17 

Print or Download PDF

Description

      

 

Installation Features

Store at  -40 to +70 °C
Install at  -10 to +50 °C, bend minimum 20 times O.D.
Operate at : -40 to +90 °C, bend minimum : 20 times O.D.
Pull maximum : 1000N

 

Design

Fiber Optic, 4 cores
Fiber: 125/250μm SM or MM (see Fiber Characteristics datasheets)
Buffer: PBTP tube nominal diam 1.8mm filled with jelly, colour natural
Fire barrier: mica tape
Colour code: 1.Blue  2.Orange  3.Green  4.Brown
Protection: Glass yarns (alternatively aramide yarns)
Jacket: LSZH Orange, nominal thickness 0.7mm, nominal outer Ø 4.0mm

Power 3 conductors 2.5mm²
Conductor :  stranded tinned copper 2.5mm2
Fire barrier: mica tape
Insulation :  XLPE, nominal Ø 3.5mm, colour coded (1.Blue, 2.Brown, 3.Green/Yellow)
Conductor resistance @ 20°C :  ≤ 8.21 Ω/km
insulation resistance @ 20°C :  ≥ 1GΩ x km
Test Voltage :  2000V AC x 1 minute
Operating Voltage :  300/500V 

Assembling
Cable core :  power and fiber elements stranded together around a central filler and wrapped by synthetic tape
Inner jacket :  non-corrosive thermoplastic LSZH compound, orange colour, nom. Ø 11.0mm
Armour :  galvanised steel, tinned copper or bronze braid, coverage ≥80%
Outer jacket : non-corrosive compound LSZH SHF1, orange colour 
Marking: APS Finland – ww/yy – ARMOURED COMPOSITE CABLE 4x… + 3×2.5mm2 – P/N – LSZH SHF1 IEC60331 IEC60332-3-22 Cat.A – lot – CE + meter

 

Environmental properties and Fire Performances

Degree of acidity of gases :  IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10μS/mm)
Halogen acid gas :  IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission :  IEC 61034-2, EN 50268-2 (Transmittance ≥ 60%)
Toxicity of evolved gas :  EN50305 9.2
Flame retardant :  IEC 60332-1-2
Fire retardant :  IEC 60332-3-22 Cat.A
Fire resistant:  IEC 60331
Oil resistant :  intermittent splash
UV resistant :  IEC60811-2-1, ASTM-D-2565-92A

 

Ordering and delivery information

Cable typeP/NO.D [mm]Packaging
Armoured GSWBOCX3254xxHF115.0500m/1640ft drum (+/-5%)
Armoured TCWBOCX3254xxHT115.0500m/1640ft drum (+/-5%)
Armoured BWBOCX3254xxHB115.0500m/1640ft drum (+/-5%)
Armoured GSWAOCX3254xxHA116.0500m/1640ft drum (+/-5%)

XX =  fiber type = OS2 = S2, OM1=M1, OM2=M2, OM3=M3, OM4=M4, OM5=M5.

Standards of reference

IEC 60092-370Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units.
CEI EN 50289 Communication cables - Specifications for test methods
EN 50290-2-23 Insulation materials for telecommunication cables
IEC 60811 Insulating and sheathing materials of electric cables - Test method
IEC 60793General specifications for both multimode and single-mode optical fibres
IEC 60794General specifications for optical fibre cables

 Engineered by APS Team

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

SKU: OCX3254xxHoo1 Categories: , ,