CCTV composite cable 2xCoax 75Ohm, Signal 2x2x0.22mm2, Power 4×2.5mm2, Armoured, MUD Resistant

2xCoax RG59-Mini, Signal 2 pairs 0.22mm2, Power 4×2.5mm2, LSZH, Armoured GSWB, Fire Retardant IEC60332-3-24 Cat.C
OC7522P425KAU, 11.05.2016/H/AP rev.1

 

Print or Download PDF

Description

   

 

 

Store at : -10 to +70 °C
Install at : -10 to +50 °CBend minimum : 20 x O.D.
Operate at : -60 to +90 °CBend minimum : 25 x O.D.

Design

2 x Coax 75Ohm 

Inner conductor : stranded bare copper 7×0.20mm (0.22mm2)
Dielectric : polyethylene nominal Ø 2.44

Braid : bare copper 
Sheath : non-corrosive thermoplastic compound, Low Smoke Zero Halogen nominal Ø 3.81mm (numbered 1 and 2)
Impedance    75 ± 3 Ω/km (@ 5 MHz)
Capacitance  55 pF/m (@ 1 KHz)

Attenuation   3.3 dB/100m
Max cable length 250m
 

Signal, 2 pairs 0.22mm2

Conductor : stranded tinned copper 7×0.20
Insulation : halogen free polyethylene 
Assembling : no 2 conductors colour coded (1.White/Blue, 2.White/Orange) stranded together into a pair.
Screen : aluminium/polyester tape 100% coverage with tinned copper drain wire 0.2mm2 
Sheath : non-corrosive thermoplastic compound, LSZH, nom. Ø 2.2mm, colour coded (1.Black 2.Grey)
 

Power, 4 cores 2.5mm2

Conductor : stranded bare copper 2.5mm2
Insulation : cross linked polyethylene nominal Ø 3.3mm, colour coded (1.Red, 2.Blue, 3.Green, 4.Yellow)
Conductor resistance @ 20°C : ≥ 8.21 Ω/km
Insulation resistance @ 20°C : ≥ 5000 MΩ x km
Test Voltage : 2000 V AC x 1 minute

Assembling

Cable core : coaxial, signal and power elements stranded together into a compact core, with fillers and wrapping if necessary
Screen :  tinned copper braid, coverage 80%
Inner jacket:  thermoplastic compound LSZH , nom. thick. 0.80mm, orange colour
Strain relief:  braided kevlar
Armour : galvanized steel wire braid 

Outer jacket:  LSZH MUD Resistant , nom. thick. 1.50mm, orange colour
Marking : APS Finland – ww/yy – ARMOURED COMPOSITE CABLE – description + P/N – MUD RESISTANT NEK606 – IEC60332-3-24 – lot + m

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN50305 9.2
Flame retardant : IEC 60332-1-2
Ozone resistant : IEC60811-2-1, DIN VDE 0472 part 805 B
Weather resistant : ASTM G 154, EN 11507
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC60811, IRM 903
MUD resistant : NEK606:2009, IEC60092-350
Water absorption : IEC60811-1-3
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Cold bend and impact : CSA C22.2

 

 

 

Ordering and delivery information

  Cable type P/N O.D [mm] Weight [kg/km] Packaging 
2x75Ohm + 2P0.22 + 4x2.5OC7522P425KAU 21.1670drum 500m (+/-5%) 

 

 

 

Other standards of reference

 

IEC 60092-370Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units.
CEI EN 50289 seriesCommunication cables - Specifications for test methods
MIL-C-17General specification for radio frequency coaxial cables
IEC61196-1Coaxial communication cables
EN 50290-2-23Insulation materials for telecommunication cables
IEC 60811Insulating and sheathing materials of electric cables - Test method

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. 

 

 

 

 

 

 

SKU: OC7522P425KAU Categories: , ,