Description
Store at : -10 to +70 °C
Install at : -10 to +50 °C, Bend minimum : 20 x O.D.
Operate at : -40 to +80 °C, Bend minimum : 25 x O.D.
Design
Coaxial, 75Ohm RG59
Inner conductor : solid bare copper wire Class 1 0.58mm
Dielectric : polyethylene nominal Ø 3.70
Braid : bare copper, coverage ≥95%
Sheath : non-corrosive thermoplastic compound, Low Smoke Zero Halogen nominal Ø 6.15 mm
Velocity : 66%
Capacitance : 67 pF/m
Resistance conductor : 154 ± 5 Ω/km
Resistance braid : 9 ± 3 Ω/km
Attenuation : @ 500MHz 24.8 dB/100m
Attenuation : @ 1000MHz 35.6 dB/100m
Attenuation : @ 3000MHz 67.7 dB/100m
Return Loss : @ 3000MHz > 14.0 bB
Signal, 2 pairs AWG24
Conductor : stranded tinned copper AWG24/7 strands
Insulation : polyethylene nominal thickness 0.40mm
Assembling : no 2 insulated conductors colour coded (1.White, 2.Black) stranded together into a pair.
Screen : aluminium/polyester tape 100% coverage with tinned copper drain wire
Sheath : non-corrosive thermoplastic compound, LSZH, nom. Ø 4.8mm, colour coded (1.Black 2.Grey)
Resistance of conductor @ 20°C : 90 Ω/km
Insulation resistance @ 20°C : ≥ 1000 MΩ x km
Test Voltage : 1000 V DC x 1 minute
Power, 3 cores 1.5mm2
Conductor : stranded tinned copper 2.5mm2
Insulation : cross linked polyethylene nominal Ø 3.5mm, colour coded (1.Blue, 2.Brown, 3.Green/Yellow)
Conductor resistance @ 20°C : 8.21 Ω/km
Insulation resistance @ 20°C : ≥ 5000 MΩ x km
Test Voltage : 2000 V AC x 1 minute
Assembling
Cable core : coaxial, signal and power elements stranded together into a compact core, with fillers and wrapping
Inner jacket (outer for unarmoured version): crosslinked thermoplastic compound, LSZH SHF2, nom. thick. 0.80mm, black
Marking : APS Finland – ww/yy – COMPOSITE CABLE OC75592P243252 – SHF2 IEC60332-3-24 – lot + m
Armoured version
Armour : galvanized steel wire braid, coverage ≥85% (Alternatives : Bronze braid, Tinned Copper braid, Stainless steel wire)
Outer jacket : crosslinked thermoplastic compound, LSZH SHF2, nom. thickness 1.50mm, black colour
Marking : APS Finland – ww/yy – ARMOURED COMPOSITE CABLE – P/N – SHF2 IEC60332-3-24 – lot + m
Environmental properties and Fire Performances
Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10μS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24 Cat.C
Ozone resistant : IEC60811-2-1, DIN VDE 0472 part 805 B
LSZH SHF2 : IEC60092-360
Oil resistant : IEC60811
Water absorption : IEC60811-1-3
Water penetration : NO
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Ordering and delivery information
Cable type | P/N | O.D [mm] | Weight [kg/km] | Packaging |
---|---|---|---|---|
Unarmoured | OC75592P243252 | 16.0 | 380 | drum 500m (+/-5%) |
Armoured GSWB | OC75592P24325HF2 | 21.0 | 480 | drum 500m (+/-5%) |
Armoured GSWA | OC75592P24325HA2 | 23.0 | 500 | drum 500m (+/-5%) |
Armoured Bronze braid | OC75592P24325HB2 | 23.0 | 480 | drum 500m (+/-5%) |
Armoured St. Steel braid | OC75592P24325HS2 | 24.0 | 540 | drum 500m (+/-5%) |
Other standards of reference
IEC 60092-370 | Electrical installations in ships: Guidance on the selection of cables for telecommunication and data. |
IEC 60092-360 | Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. |
CEI EN 50289 series | Communication cables - Specifications for test methods |
MIL-C-17 | General specification for radio frequency coaxial cables |
IEC61196-1 | Coaxial communication cables |
EN 50290-2-23 | Insulation materials for telecommunication cables |
IEC 60811 | Insulating and sheathing materials of electric cables - Test method |
Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed.