Description
Store at : -10 to +70 °C
Install at : -10 to +50 °C, Bend minimum : 20 x O.D.
Operate at : -34 to 80 °C, Bend minimum : 25 x O.D.
Design
Coaxial, 75Ohm RG59
Inner conductor : solid bare copper wire Class 1 0.58mm
Dielectric : polyethylene nominal Ø 3.70
Braid : bare copper, coverage ≥95%
Sheath : non-corrosive thermoplastic compound, Low Smoke Zero Halogen nominal Ø 6.15 mm
Velocity : 66%
Capacitance : 67 pF/m
Resistance conductor : 154 ± 5 Ω/km
Resistance braid : 9 ± 3 Ω/km
Attenuation : @ 500MHz 24.8 dB/100m
Attenuation : @ 1000MHz 35.6 dB/100m
Attenuation : @ 3000MHz 67.7 dB/100m
Return Loss @ 3000MHz : > 14.0 dB
Signal, 2 pairs AWG24
Conductor : stranded tinned copper AWG24/7 strands
Insulation : polyethylene nominal thickness 0.40mm
Assembling : no 2 insulated conductors colour coded (1.White, 2.Black) stranded together into a pair.
Screen : aluminium/polyester tape 100% coverage with tinned copper drain wire
Sheath : non-corrosive thermoplastic compound, LSZH, nom. Ø 4.8mm, colour coded (1.Black 2.Grey)
Resistance of conductor @ 20°C : 90 Ω/km
Insulation resistance @ 20°C : ≥ 1000 MΩ x km
Test Voltage : 1000 V DC x 1 minute
Power, 3 cores 2.5mm2
Conductor : stranded tinned copper 2.5mm2
Insulation : cross linked polyethylene nominal Ø 3.0mm, colour coded (1.Blue, 2.Brown, 3.Green/Yellow)
Conductor resistance @ 20°C : 8.21 Ω/km
Insulation resistance @ 20°C : ≥ 1GΩ x km
Test Voltage : 2000 V AC x 1 minute
Assembling
Cable core : coaxial, signal and power elements stranded together into a compact core, with fillers and wrapping
Inner jacket (outer for unarmoured version): SHF1 thermoplastic compound, nom. thickness 0.80mm, black colour
Marking : APS Finland – ww/yy – COMPOSITE CABLE P/N – SHF1 IEC60332-3-24 – lot + m
Armoured version
Armour : galvanized steel wire braid, coverage ≥85% (Alternatives : Bronze braid, Stainless steel braid)
Outer jacket : non-corrosive thermoplastic compound, SHF1, nom. thickness 1.50mm, black colour
Marking : APS Finland – ww/yy – ARMOURED COMPOSITE CABLE P/N – SHF1 IEC60332-3-24 – lot + m
Environmental properties and Fire Performances
Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24 Cat.C
Oil resistant : intermittent splash – permanent resistance available upon request
Water penetration : NO
Ordering and delivery information
Cable type | P/N | O.D [mm] | Weight [kg/km] | Packaging | |
---|---|---|---|---|---|
Unarmoured | OC75592P243251 | 17.0 | 380 | drum 500m (+/-5%) | |
Armoured GSWB | OC75592P243251F21 | 22.0 | 480 | drum 500m (+/-5%) | |
Armoured GSWA | OC75592P243251FA1 | 24.0 | 500 | drum 500m (+/-5%) | |
Armoured Bronze braid | OC75592P243251FB1 | 22.0 | 480 | drum 500m (+/-5%) | |
Armoured St. Steel braid | OC75592P243251SA1 | 24.0 | 540 | drum 500m (+/-5%) |
Other standards of reference
IEC 60092-370 | Electrical installations in ships: Guidance on the selection of cables for telecommunication and data. |
IEC 60092-360 | Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. |
CEI EN 50289 series | Communication cables - Specifications for test methods |
MIL-C-17 | General specification for radio frequency coaxial cables |
IEC61196-1 | Coaxial communication cables |
EN 50290-2-23 | Insulation materials for telecommunication cables |
IEC 60811 | Insulating and sheathing materials of electric cables - Test method |