Description
Store at : -10 to +70 °C
Install at : -10 to +50 °C, Bend minimum : 20 x O.D.
Operate at : -35 to +80 °C, Bend minimum : 25 x O.D.
Design
2 x 75Ohm RG59
Inner conductor : solid bare copper wire Class 1 0.58mm
Dielectric : polyethylene nominal Ø 3.70
Braid : bare copper, coverage ≥95%
Sheath : non-corrosive thermoplastic compound, Low Smoke Zero Halogen nominal Ø 6.15 mm
Velocity : 66%
Capacitance : 67 pF/m
Resistance conductor : 154 ± 5 Ω/km
Resistance braid : 9 ± 3 Ω/km
Attenuation @ 500MHz : 24.8 dB/100m
Attenuation @ 1000MHz : 35.6 dB/100m
Attenuation @ 3000MHz : 67.7 dB/100m
Return Loss @ 3000MHz : > 14.0 dB
Signal, 2 pairs AWG24
Conductor : stranded tinned copper AWG24/7 strands
Insulation : polyethylene nominal thickness 0.40mm
Assembling : no 2 insulated conductors colour coded (1.White, 2.Black) stranded together into a pair.
Screen : aluminium/polyester tape 100% coverage with tinned copper drain wire
Sheath : non-corrosive thermoplastic compound, LSZH, nom. Ø 4.8mm, colour coded (1.Black 2.Grey)
Resistance of conductor @ 20°C : 90 Ω/km
Insulation resistance @ 20°C : ≥ 1000 MΩ x km
Test Voltage : 1000 V DC x 1 minute
Power, 2 cores 2.5mm2
Conductor : stranded tinned copper 2.5mm2
Insulation : cross linked polyethylene nominal Ø 3.5mm, colour coded (1.Blue, 2.Brown, 3.Green/Yellow)
Conductor resistance @ 20°C : ≥ 8.21 Ω/km
Insulation resistance @ 20°C : ≥ 5000 MΩ x km
Test Voltage : 2000 V AC x 1 minute
Assembling
Cable core : coaxial, signal and power elements stranded together into a compact core, with fillers and wrapping
Inner jacket (outer for unarmoured version): : thermoplastic compound LSZH SHF1, nom. thick. 0.80mm, black
Marking : APS Finland – ww/yy – COMPOSITE CABLE OC752592P243251 – SHF1 IEC60332-3-24 – lot + m
Armoured version
Armour : galvanized steel wire braid, coverage ≥85% (Alternatives : Bronze braid, Tinned Copper braid, Stainless steel wire)
Outer jacket : thermoplastic compound LSZH SHF1, nom. thickness 1.50mm, black colour
Marking : APS Finland – ww/yy – ARMOURED COMPOSITE CABLE – P/N – SHF1 IEC60332-3-24 – lot + m
Environmental properties and Fire Performances
Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24 Cat.C
Oil resistant : intermittent splash – permanent resistance available upon request
Water penetration : NO
Ordering and delivery information
Cable type | P/N | O.D [mm] | Weight [kg/km] | Packaging |
---|---|---|---|---|
Unarmoured | OC752592P243251 | 16.5 | 420 | drum 500m (+/-5%) |
Armoured GSWB | OC752592P24325HF1 | 19.6 | 580 | drum 500m (+/-5%) |
Armoured GSWA | OC752592P24325HA1 | 21.0 | 630 | drum 500m (+/-5%) |
Armoured Bronze braid | OC752592P24325HB1 | 19.6 | 580 | drum 500m (+/-5%) |
Armoured St. Steel braid | OC752592P24325HS1 | 19.6 | 620 | drum 500m (+/-5%) |
Other standards of reference
IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units.
CEI EN 50289 series Communication cables - Specifications for test methods
MIL-C-17 General specification for radio frequency coaxial cables
IEC61196-1 Coaxial communication cables
EN 50290-2-23 Insulation materials for telecommunication cables
IEC 60811 Insulating and sheathing materials of electric cables - Test method