Description
Store at : -40 to +70 °C
Install at : -10 to +50 °C, Bend minimum : 20 times O.D.
Operate at : -40 to +80 °C, Bend minimum : 20 times O.D
Design
Coaxial 2 x 75Ohm RG11
Inner conductor : stranded tinned copper 7×0.40mm
Dielectric : PE + Silicone Ø 7.25 ± 0.18 mm
Braid : bare copper, coverage 97%
Wrapping : non-migrating polyester tape
Sheath : non-corrosive thermoplastic compound, Low Smoke Zero Halogen Ø 10.3 ± 0.20 mm
Velocity : 66%
Capacitance : 67 pF/m
Resistance conductor : 20.5 Ω/km R
Resistance braid : 4.5 Ω/km
Attenuation @ 500MHz : 15.5 dB/100m
Attenuation @ 1000MHz : 23.4 dB/100m
Return Loss @ 900MHz : > 20.0 dB
Screening effectiveness : > 25.0 dB
2 pairs AWG22
Conductor : stranded tinned copper AWG22/7 (0.88mm2)
Insulation : Mica+XLPE or silicon (nominal Ø 3.00mm)
Assembling : no 2 insulated conductors colour coded (1.White, 2.Black) stranded together into a pair.
Screen : aluminium/polyester tape 100% coverage with tinned copper drain wire
Sheath : non-corrosive thermoplastic compound, LSZH, nom. Ø 4.3mm, colour coded (1.Black 2.Blue)
Resistance of conductor @ 20°C :≤ 90 Ω/km
Insulation resistance @ 20°C : ≥ 1000 MΩ x km
Test Voltage : 1000 V DC x 1 minute
Power, 2 cores 2.5mm2
Conductor : stranded tinned copper 2.5mm2
Insulation : Mica+XLPE or silicon nominal Ø 3.5mm, colour coded (1.Black, 2.Red, 3.Green/Yellow)
Conductor resistance @ 20°C : ≤ 7.98 Ω/km
Insulation resistance @ 20°C : ≥ 5000 MΩ x km
Test Voltage : 2000 V AC x 1 minute
Assembling
Cable core : coaxial, signal and power elements stranded together into a compact core, with fillers and wrapping
Inner jacket (outer for unarmoured version): : SHF1 thermoplastic compound LSZH, Ø 17.5mm, black colour
Marking : APS Finland – ww/yy – ARMOURED COMPOSITE CABLE OCX752112P223251 – IEC60331-23 IEC60332-3-24 – lot + m
Armoured version
Armour : galvanized steel wire braid, coverage ≥80% (alternatives : Bronze braid, Stainless steel braid)
Outer jacket : SHF1 thermoplastic compound LSZH, black colour
Marking : APS Finland – ww/yy – ARMOURED COMPOSITE CABLE OC7511P223251F1 – IEC60331-23 IEC60332-3-24 – lot + m
Environmental properties and Fire Performances
Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24 Cat.C
Fire resistant : IEC 60331
Oil resistant : intermittent splash – permanent resistance available upon request
Water penetration : NO
Ordering and delivery information
Cable type | P/N | O.D [mm] | Weight [kg/km] | Packaging |
---|---|---|---|---|
Unarmoured | OCX752112P223251 | 26.0 | 780 | drum 500m (+/-5%) |
Armoured GSWB | OCX752112P223251F21 | 29.0 | 950 | drum 500m (+/-5%) |
Armoured GSWA | OCX752112P223251 FA1 | 30.0 | 1100 | drum 500m (+/-5%) |
Armoured Bronze braid | OCX752112P223251 FB1 | 29.0 | 950 | drum 500m (+/-5%) |
Armoured St. Steel braid | OCX752112P22325 1SA1 | 29.0 | 980 | drum 500m (+/-5%) |
Other standards of reference
IEC 60092-370 | Electrical installations in ships: Guidance on the selection of cables for telecommunication and data. |
IEC 60092-360 | Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. |
CEI EN 50289 series | Communication cables - Specifications for test methods |
MIL-C-17 | General specification for radio frequency coaxial cables |
IEC61196-1 | Coaxial communication cables |
EN 50290-2-23 | Insulation materials for telecommunication cables |
IEC 60811 | Insulating and sheathing materials of electric cables - Test method |
Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed.