Description
Store at : -40 to +80 °C
Install at : -10 to +50 °C, Bend minimum : 15 times O.D.
Operate at : -40 to +80 °C, Bend minimum : 12 times O.D.
Pull maximum : 1000N
Crush maximum : 200N/100mm
Design
Fiber optic 6 Cores
Fiber : Fiber: 125/250µm SM or MM (see Fiber Characteristics datasheets)
Buffer : PBTP tube filled with jelly
Colour code : 1.Blue 2.Orange 3.Green 4.Brown 5.Grey 6.White
Protection : Glass yarns (alternatively aramide yarns)
Jacket : LSZH Orange, nominal thickness 0.7mm, nominal outer Ø 4.0mm
Power, 3 cores 2.5mm2
Conductor : stranded tinned copper 2.5mm2 (Class 2 or Class 5)
Insulation : cross linked polyethylene (XLPE) nominal Ø 3.7mm, colour coded (1.Brown, 2.Blue, 3.Grey)
Conductor resistance @ 20°C : ≤ 8.21 Ω/km
Insulation resistance @ 20°C : ≥ ≥ 1GΩ x km
Operating Voltage : 600/1000V
Test Voltage : 3500 V AC x 1 minute
Assembling
Cable core : power and fiber elements stranded together (around a central element if necessary)
Inner jacket (outer for non-armoured version) : non-corrosive thermoplastic compound, LSZH, black colour
Marking (non-armoured version) : APS Finland – ww/yy – COMPOSITE CABLE P/N – LSZH IEC60332-3-24 Cat.C – lot + m
Armour : galvanized steel concentric wires or braid, coverage ≥85%
Outer jacket : non-corrosive thermoplastic compound LSZH, UV-Resistant, black colour
Marking : APS Finland – ww/yy – ARMOURED COMPOSITE CABLE P/N – LSZH IEC60332-3-24 Cat.C – lot + m
Environmental properties and Fire Performances
Degree of acidity of gases : IEC 60754-1, IEC 60754-2
Halogen acid gas : IEC 60754-1, IEC 60754-2
Smoke Emission : IEC 61034-2
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24 Cat.C
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Ordering and delivery information
P/N | O.D [mm] | Packaging |
---|---|---|
OC3256xxH non-armoured | 11.0 | drum 500m (+/-5%) |
OC3256xxHFH armoured GSWB | 15.0 | drum 500m (+/-5%) |
OC3256xxHAH armoured SWA | 16.5 | drum 500m (+/-5%) |
xx = Fiber type : OS2=S2 – OM1=M1 – OM2=M2 – OM3=M3 – OM4=M4 – OM5=M5
Other standards of reference
IEC 60092-370 | Electrical installations in ships: Guidance on the selection of cables for telecommunication and data. |
IEC 60092-360 | Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. |
CEI EN 50289 series | Communication cables - Specifications for test methods |
MIL-C-17 | General specification for radio frequency coaxial cables |
IEC61196-1 | Coaxial communication cables |
EN 50290-2-23 | Insulation materials for telecommunication cables |
IEC 60811 | Insulating and sheathing materials of electric cables - Test method |