Description
Store at : -5 to +65 °C
Install at : -5 to +65 °C, Bend minimum : 15 times O.D.
Operate at : -20 to +80 °C, Bend minimum : 15 times O.D.
Pull maximum : 1000N
Crush maximum : 2000N/100mm for 15 minutes
Design
Fiber optic 4 Cores
Fiber : Fiber: 125/250µm SM or MM (see Fiber Characteristics datasheets)
Buffer : PBTP tube nominal diam. 2.0mm filled with jelly
Colour code : 1.Natural 2.Red 3.Green 4.Yellow
Protection : swellable glass yarns
Jacket : PVC Orange
Power, 3 cores 2.5mm2
Conductor : stranded tinned annealed copper 2.5mm2 (according to Class 5 IEC 60228)
Insulation : cross linked polyethylene (XLPE), colour coded (1.Blue, 2.Brown, 3.Green/Yellow)
Conductor resistance @ 20°C : ≤ 8.21 Ω/km
Insulation resistance @ 20°C : ≥ 1000 MΩ x km
Operating Voltage : 600/1000V
Test Voltage : 3500 V AC x 1 minute
Assembling
Cable core : power and fiber elements stranded together around a central filler
Wrapping: PET
Inner jacket: PVC, nom. Ø 10.6mm, colour black or according to customer’s requirements
Armour : galvanized steel wire braid
Outer jacket : PVC compound, nom. Ø 14.8mm, colour black or according to customer’s requirements
Marking : APS Finland – ARMOURED COMPOSITE CABLE – 4xOS2 + 3×2.5mm2 – P/N – PVC UVR +65°C – IEC 60332-3-22 Cat.A – BATCH *****/** + meter marking.
Environmental properties and Fire Performances
Acid gas emission : IEC 60754-1 (HCl ≤ 22%)
Smoke emission : IEC 61034-2 (Transmittance) ≥ 20%)
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Ordering and delivery information
P/N | Colour (inner and outer jacket) | O.D [mm] | Weight [kg/km] | Packaging | Tolerance |
---|---|---|---|---|---|
OC3254xxVFV | Yellow | 14.8 | 340 | drum 500m or 1000m | +/-5% |
OC3254xxVFV_BK | Black | 14.8 | 340 | drum 500m or 1000m | +/-5% |
xx = Fiber type : OS2=S2 – OM1=M1 – OM2=M2 – OM3=M3 – OM4=M4 – OM5=M5