75 Ohm Coaxial cable RG6 CCS double screen PVC

CATV RG6 CCS, double screen, 75Ohm.
CCS6AB6VKB3, Rev.00, Date 2017-11-16

Print or Download PDF

Description

 

Installation Features

Store at  -10 to +50 °C
Install at  -10 to +50 °C, Bend minimum : 20 times O.D.
Operate at : -0 to +60 °CBend minimum : 20 times O.D.
Pull maximum : 100N

 

Design

Conductor :  solid CCS 1.02mm
Dielectric :  foam PE nominal Ø 4.60mm
Screen 1 :  bonded AL/P nominal Ø 4.75mm
Screen 2 :  Aluminium wire braid nominal coverage 60%

Jacket : black PVC material nominal Ø 6.86mm
Marking :  APS Finland – ww/yy – 75 Ohm CATV RG6 CCS – P/N CCS6AB6VKB3 – lot – meter

 

Environmental properties and Fire Performances

Flame retardant : IEC60332-1-2

 

Electrical Characteristics

Characteristic impedance (Ohm)75+/-3
Capacitance (pF/m)52+/-2
Velocity of Propagation (%)85.0
Return Loss (dB) 5-1000MHz≥22

FrequencyAttenuation
db/100ft
Attenuation
dB/100 meter
551.65.2
1872.89.3
2113.110
4004.113.5
5004.615.0
7505.618.5
8606.120.0
10006.621.5

 

Recommended connectivity

BNC connectors : APS BNC75

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.