MOG Cat.7 S/FTP 4 pairs stranded conductor AWG23/7 SHF1

EMC screened, stranded conductor SHF1, Fire Retardant IEC60332-3-22 Cat.A
O7SF4P23F1, 23.03.2014/AP rev.5
Type Approval: DNV TAE000004C_R5

 

Print or Download PDF

Description

 

    

 

Store at : -0 to +50 °C
Install at : -10 to +50 °CBend minimum : 5 times O.D.
Operate at : -30 to +80 °CBend minimum : 10 times O.D.
Pull maximum : 100N
Cable weight : 80 kg/km

 

Design

Conductor : Stranded bare copper 7×0.22 AWG23 (0,28mm2)
Insulation : Cellular polyolefin Ø1.5mm
Pair : 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown
Screen 1 : Aluminium/polyester or Aluminium/polyester/aluminium tape over each single pair
Screen 2 : tinned copper wire braid 
Outer jacket : Grey RAL7035 Fire Retardant and UV Resistant SHF1 material, LSZH (nom. Ø 8.6mm)
Marking :  APS Finland – ww/yy – SFTP Flex 4x2x23AWG Cat.7 SHF1 – IEC60332-3-22 Cat A – lot + m

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Oil resistant : intermittent splash – permanent resistance available upon request
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

 

Electrical characteristics (IEC 60811, EN 50288-4-2)

Test voltage : 0.7kV a.c. for 1 minute
Resistance of the conductor @ 20°C : ≤ 69,5 /km

Insulation resistance : ≥ 500 MΩxkm
Nominal Capacitance @ 800÷1000MHz : 45 pF/m
Average characteristic impedance : 100 ± 5 Ω @ 100MHz Transfer impedance : ˂ 3mΩ/m @ 10MHz

Frequency (MHz) : 10 1631,25 62,5 100 155 200 300 400 500 600 9001000
Attenuation dB/100m (nominal) 1.73.25.26.59.413.617.022.224.330.235.239.143.555.258.1
NEXT dB (nominal) 1051051051051051031009895939087858180
ACR dB/100m (nominal) 103102100989689837671735548412622
ELFEXT dB (nominal) 959392918682777370676462605350
Return Loss dB (nominal) 25 28 30 30 30 30302826252423232120

 

Ordering and delivery information

Pair countP/NO.D [mm]Weight [kg/km]Packaging
4 pairsO7SF4P23F18.690500 m (+/-5%)

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2Type Approval Program
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
CEI EN 50288-1Multi-element metallic used in analogue and digital communication and control : Generic Specification
CEI EN 50288-2-1Setional specification for screened cables characterised up to 100MHz
CEI EN 50288-5-1Setional specification for screened cables characterised up to 250MHz
CEI EN 50288-4-2Setional speci cation for screened cables characterised up to 600MHz
CEI EN 50289 seriesCommunication cables - Specifications for test methods
IEC 60811Insulating and sheathing materials of electric cables - Test method
Standards EIA/TIA 568-C.2, ISO/IEC 11801, UL444, UL1581, UL1666
Applications 100Base-TX, 100Base-T, 100VG-AnyLAN, 1000Base-TX, ATM

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

SKU: O7SF4P23F1 Categories: , ,