MOG Cat.7 S/FTP 4 pairs AWG23/7 SHF1 Armoured

EMC screened, stranded conductor, armoured SHF1, Fire Retardant IEC60332-3-22 Cat.A
O7SF4P23F1_1, 02.05.2015/AP rev.1
Type Approval: DNV TAE000004E_R4

 

Print or Download PDF

Description

     

 

Store at : 0 to +50 °C
Install at : -10 to +50 °CBend minimum : 20 times O.D.
Operate at : -30 to +80 °CBend minimum : 15 times O.D.
Pull maximum : 100N

 

Design

Conductor :Stranded bare copper AWG23/7
Insulation :
Cellular polyolefin Ø1.5mm

Pair : 2 insulated conductors stranded together into a pair
Colour code :1.White/blue 2.White/orange 3. White/green 4.White/brown (IEC 708-1)
Screen 1 :
Aluminium/polyester or Aluminium/polyester/aluminium tape over each single pair

Screen 2 : Tinned Copper wire braid
Inner jacket : Grey Fire Retardant and UV Resistant SHF1 material, LSZH (nominal Ø 8.3mm)
Armour : Galvanized steel, tinned copper or bronze braid. minimum coverage 80%.
Outer jacket : Grey RAL7035 Fire Retardant and UV Resistant SHF1 material, LSZH (nominal thickness 1.0mm)
Marking :  APS Finland – ww/yy – ARMOURED SFTP Flex 4x2x23AWG Cat.7 SHF1 – IEC60332-3-22 Cat A – lot + m

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : NO
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

 

 

Electrical characteristics (IEC 60811, EN 50288-4-2) 

Test voltage : 0.7kV a.c. for 1 minute
Resistance of the conductor @ 20°C : ≤ 69,5 /km
Insulation resistance : ≥ 500 MΩxkm
Nominal Capacitance @ 800÷1000MHz : 45 pF/m
Average characteristic impedance : 100 ± 5 Ω @ 100MHz
Transfer impedance : ˂ 3mΩ/m @ 10MHz

Frequency (MHz) : 10 1631,25 62,5 100 155 200 300 400 500 600 9001000
Attenuation dB/100m (nominal) 1.73.25.26.59.413.617.022.224.330.235.239.143.555.258.1
NEXT dB (nominal) 1051051051051051031009895939087858180
ACR dB/100m (nominal) 103102100989689837671735548412622
ELFEXT dB (nominal) 959392918682777370676462605350
Return Loss dB (nominal) 25 28 30 30 30 30302826252423232120

 

Ordering and delivery information

Pair countP/NO.D [mm]Weight [kg/km]Packaging
4 pairs, GSWBO7SF4P23F1A111.4140500 m (+/-5%)
4 pairs, BWBO7SF4P23F1B111.4150500 m (+/-5%)
4 pairs, TCWBO7SF4P23F1T111.4135500 m (+/-5%)

 

 

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2Type Approval Program
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
CEI EN 50288-1Multi-element metallic used in analogue and digital communication and control : Generic Specification
CEI EN 50288-2-1Setional specification for screened cables characterised up to 100MHz
CEI EN 50288-5-1Setional specification for screened cables characterised up to 250MHz
CEI EN 50288-4-2Setional speci cation for screened cables characterised up to 600MHz
CEI EN 50289 seriesCommunication cables - Specifications for test methods
IEC 60811Insulating and sheathing materials of electric cables - Test method
Standards EIA/TIA 568-C.2, ISO/IEC 11801, UL444, UL1581, UL1666
Applications 100Base-TX, 100Base-T, 100VG-AnyLAN, 1000Base-TX, ATM

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, APS Cables & Connectors Oy cannot be considered responsible for any mistake in this document and users should consult APS Cables & Connectors Oy for any information needed. APS Cables & Connectors Oy reserves the right to make changes to the documents at any time, without prior notice.

SKU: O7SF4P23F1_1 Categories: , ,