Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the wa_wcc_txt domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /var/www/vhosts/aps-finland.fi/httpdocs/wp-includes/functions.php on line 6170
MOG Cat.6 LAN cable U/UTP 4 pairs SHF1 - APS Finland

MOG Cat.6 LAN cable U/UTP 4 pairs SHF1

Category 6, unscreened, 4 pairs, PVC

Print or Download PDF

Description

Store at : -40 to +70 °C
Install at : -40 to +70 °C
Operate at : –40 to +70 °C
Bend minimum : 10 times O.D.
Bend minimum : 10 times O.D.
Pull maximum : 40N

Design

Conductor : solid bare copper AWG23
Insulation : polyethylene
Pair : 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown
Assembling : no 4 pairs assembled together around a PE central cross
Screen : aluminium/mylar tape (coverage 100%) with tinned copper drain wire 0.50mm
Inner jacket : grey Fire Retardant SHF1 material (nominal Ø 7.2mm)
Outer jacket : grey or black Fire Retardant SHF1 UV-Resistant material (nominal Ø 8.6mm)
Marking : APS Finland – ww/yy – U/UTP 4x2xAWG23/1 Cat.6 SHF1 – IEC60332-3-22 Cat A – lot + meter

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : NO
Ozone resistant : upon request
Weather resistant : upon request
LSZH SHF2 : upon request
Oil resistant : intermittent splash – permanent resistance available upon request
MUD resistant : upon request
Water absorption : upon request
Water penetration : NO
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

Electrical characteristics

Test voltage : 2500 V DC for 2 minutes
Resistance of the conductor @ 20°C : ≤ 68 Ω/km
Insulation resistance : ≥ 5 GΩxkm
Nominal Capacitance : 52 pF/m (cond/cond)
Average characteristic impedance : 100 ± 5 Ω @ 100MHz

[table “2” not found /]

Ordering and delivery information

[table “3” not found /]

 

Recommended connectivity

Keystone jack : MJ6UK / RJ45
plug : P456UAPS
Panel : OPPE24SU
Patchcords : PCMJ6U_WLZ

Other standards of reference

IEC 60092-370 : Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 : Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units.
DNV TAP 827.50/2 : Type Approval Program
ABS SVR : Rules for building and classing. Steel Vessels.
ABS SMR : Rules for building and classing. Steel vessels under 90 meters.
CEI EN 50288-1 : Multi-element metallic used in analogue and digital communication and control : Generic Specification
CEI EN 50288-4-2 : Setional specification for screened cables characterised up to 600MHz
CEI EN 50289 : series Communication cables – Specifications for test methods
IEC 60811 : Insulating and sheathing materials of electric cables – Test method