Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the wa_wcc_txt domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /var/www/vhosts/aps-finland.fi/httpdocs/wp-includes/functions.php on line 6121
MOG Cat.5e S/FTP 4 pairs AWG24/7 SHF2 MUD Resistant NEK606 - APS Finland

MOG Cat.5e S/FTP 4 pairs AWG24/7 SHF2 MUD Resistant NEK606

O5ESF4P24FU, 01.06.2014/AP rev.0
Type Approval : DNV GL PENDING
 

Print or Download PDF

Description

    

 

Store at : -40 to +70 °C
Install at : -40 to +70 °CBend minimum : 10 times O.D.
Operate at : -40 to +80 °CBend minimum : 10 times O.D.
Pull maximum : 100N
Cable weight : 130 kg/km

 

Design

Conductor : stranded bare copper 7×0.20 AWG24 (0,22mm2)
Insulation : polyethylene
Pair : 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown
Screen 1 : aluminium/polyester or Aluminium/polyester/aluminium tape over each single pair
Screen 2 : tinned copper braid coverage min. 60%
Inner jacket : grey Fire Retardant SHF1 material, LSZH (nominal thickness 1.0mm, Ø 8.7mm)
Outer jacket : black compound SHF2 and MUD resistant (nominal thickness 1.0mm, Ø 10.7mm)
Marking : APS Finland – ww/yy – SFTP Flex 4x2x24AWG Cat.5e SHF2 MUD Resistant – NEK606 – IEC60332-3-22 Cat A – lot + meter

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Ozone resistant : IEC60811-2-1, DIN VDE 0472 part 805 B
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC60811, IRM 903
MUD resistant : NEK606:2009, IEC60092-350
Water absorption : IEC60811-1-3
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Cold bend & impact : CSA C22.2, UL44

 

Ordering and delivery information

Pair countP/NO.D [mm]Weight [kg/km]Packaging
4 pairsO5ESF4P24FU10.7130500 or 1000 m (+/-5%)

 

Electrical characteristics

Test voltage : 700 Vrms (cond/cond and cond/screen) for 1 minute
Resistance of the conductor @ 20°C : ≤ 88 Ω/km

Insulation resistance : ≥ 500 MΩxkm
Nominal Capacitance : 52 pF/m (cond/cond)
Average characteristic impedance : 100 ± 5 Ω @ 100MHz

Frequency (MHz) :1410162031.562.5100
Attenuation (dB/100m)3.26.09.512.113.617.124.832.0
NEXT (dB)65.356.350.347.245.842.938.435.3
ELFEXT (dB)63.851.843.839.737.833.927.923.8
Return Loss23.024.125.025.025.023.621.520.1

 

Recommended connectivity

Keystone jack : KJ6ASTPNH
RJ45 plug : P456SAPS
Panel : OPPE24SU
Patchcords : PCMJ6S_

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2Type Approval Program
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
CEI EN 50288-1Multi-element metallic used in analogue and digital communication and control : Generic Specification
CEI EN 50288-2-1Setional specification for screened cables characterised up to 100MHz
CEI EN 50288-5-1Setional specification for screened cables characterised up to 250MHz
CEI EN 50288-4-2Setional speci cation for screened cables characterised up to 600MHz
CEI EN 50289 seriesCommunication cables - Specifications for test methods
IEC 60811Insulating and sheathing materials of electric cables - Test method
Standards EIA/TIA 568-C.2, ISO/IEC 11801, UL444, UL1581, UL1666
Applications 100Base-TX, 100Base-T, 100VG-AnyLAN, 1000Base-TX, ATM