Description
Store at: 0 to +50 °C
Install at: 0 to +50 °C, Bend minimum: 6 times V.D.
Operate at: -25 to +110 °C, Bend minimum: 6 times V.D.
Design
1.
Conductor material: stranded bare copper conductor 0.50 mm² (IEC60228)
Insulation: foam polyolefin compound (-47 to +70 °C).
Colour code: green.
2.
Conductor material: stranded tinned copper conductor 0.50 mm² (IEC60228)
Insulation: Z1 polyolefin compound (-50 to +80 °C).
Colour code: white, blue.
F.
Filler: if needed.
3.
Tape: polyester tape.
4-5.
Screen 1: aluminium/polyester tape + drain wire (tinned copper 0.50 mm²)
6.
Screen 2: tinned copper wire braid (con. ≥ 85%)
7.
Wrapping: Non-woven tape.
8.
Outer Sheath: black Z1 polyolefin-FR (-25 – +110ºC).
Marking: APS Finland – ww/yy – EPD CAN BUS CABLE 2×0.50 + 0.50 – 300/500V – Z1-FR +110ºC – IEC60332-1-2 – P/N – lot + meter
Environmental properties and Fire Performances
Flame retardant: IEC60332-1.2
RoHS: directive 2011/65/EU
REACH: directive 1907/2006
CE: directive 2014/35/EU
Electrical characteristics
2×0,50mm²
Nominal voltage: 300V
Test voltage: 1500V
Insulation resistance: > 100 MΩ x Km
Electrical resistance: : < 32,8 Ω/Km (NFC 32018)
Nominal impedance: 120 Ω (1MHz)
1×0,50mm²
Nominal voltage: 250V
Test voltage: 750V
Insulation resistance: > 100 MΩ x Km
Electrical resistance: : < 32,8 Ω/Km (NFC 32018)
Nominal impedance: 120 Ω (1MHz)
Ordering and delivery information
Type | P/N | Nom. O.D [mm] | Packaging (std) |
---|---|---|---|
2x0.50 + 1x0.50 | CUCANEDP1P050 | 8.6 mm | 500m (+/-5%) |
Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.