MOG CAN Bus 1&2 pairs stranded conductor 0.75mm, SHF2

EMC screened, stranded conductor SHF2 Fire Retardant IEC60332-3-22
OCB_P075F2, 15.05.2014/AP rev.2
Type Approval: DNV-GL TAE00001S6

 

Print or Download PDF

Description

 

     

 

Store at: -40 to +70 °C
Install at: -40 to +50 °CBend minimum: 15 times O.D.
Operate at: -40 to +90 °CBend minimum: 10 times O.D.
Pull maximum: 100N

 

 

Design

Conductor : Stranded bare copper 24×0.20 (0.75mm2)
Insulation : Cellular polyolefin Ø2.95mm
1 Pair : No 2 insulated conductors stranded together into a pair (Colour code : White/blue)
2 Pairs : No 4 insulated conductors stranded together into a star quad

Screen : Aluminium/polyester tape (100%)
Grounding wire : Tinned copper 24×0.20 (0.75mm2) polyolefin insulated (nominal Ø2.40mm). Colour yellow/green.
Assembling : One screened pair or quad with one grounding wire with fillers, wrapped with fire barrier tape
Overall screen : tinned copper braid (coverage ≥80%)
Outer jacket : Grey Fire Retardant and UV Resistant SHF1 material, LSZH (Ø 11.1mm)
Marking : APS Finland – ww/yy – CAN BUS Marine 1x2x0.75mm2 SHF2 – IEC60332-3-22 Cat A – TK/lot + meter

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : YES – NES 713, CEI 20-37/7
Flame retardant : YES – IEC 60332-1-2
Fire retardant : YES – IEC 60332-3-22 Cat.A
Fire resistant : NO – IEC 60331-25
Ozone resistant : YES – DIN VDE 0472 part 805 B
Weather resistant : YES – ASTM G 154, EN 11507
LSZH SHF2 : YES – IEC 60092-359:1987-03
Oil resistant : YES (oil, fuels and hydrocarbons) – IEC60811
MUD resistant : NO – NEK 606:2009
Water resistant : YES – IEC60502
Water penetration : NO – IEC 60794-1-2-F5-B
UV resistant : YES – ASTM-D-2565-92A

 

 

Ordering and delivery information

Pair countP/NO.D [mm]Weight [kg/km]Packaging
1 pairOCB1P075F211.0210500 m (+/-5%)
2 pairs (1 quad)OCB2P075F211.0240500 m (+/-5%)

 

 

 

Electrical characteristics

Operation voltage :  100V
Test voltage :  1kV d.c. for 1 minute
Resistance of the conductor @ 20°C :  ≤ 26.0 Ω/km for bare copper / ≤ 26.7 Ω/km for bare coppe

Insulation resistance @ 20°C :  ≥ 1GΩxkm (BUS conductor) / ≥ 10MΩxkm (earth conductor)
Nominal Capacitance @ 800Hz :  40 pF/m
Average characteristic impedance :  120 ± 10% @ 1MHz
Nominal attenuation :  13.2 dB/km @ 1MHz

 

 

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2Type Approval Program
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
IEC 60811Insulating and sheathing materials of electric cables - Test method

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

 

 

 

 

 

 