BOK1 fiber optic cable breakout, dielectric armoured SHF1 (AIAI-2 Multi)

up to 24 cores, dielectric armoured SHF1, Fire Retardant IEC60332-3-24
OBOK1, 07.05.2018/AP rev.0
Type Approval: DNV-GL TAE00002VE

 

Print or Download PDF

Description

 

    

 

Store at: -40 to +70 °C
Install at: -10 to +50 °CBend minimum: 15 times O.D.
Operate at: -40 to +70 °CBend minimum:10 times O.D.
Crush maximum: 4000N/100mm
Impact maximum: 10J

 

 

Design

Bare fiber : 250µm
Buffer : 900µm tight buffer
Colour code : white
Protection : aramide yarns
Inner sheath : blue LSZH material, nominal diameter 2.0mm, each numbered for identification
Cable core : up to 24 tight buffered fibers are stranded together around a central FRP member and wrapped by a synthetic tape.
Intermediate jacket : blue SHF1 UV-Resistant material, nominal thickness 1.0mm
Armour : aramide yarns.
Outer jacket : blue or black SHF1 UV-Resistant material, nominal thickness 1.2mm
Marking :  APS Finland – AIAI-2-Multi – FIBER OPTIC CABLE BOK1 [Fibre type and No of fibres] – IEC 60332-3-24 – Lot No + meter marking [A]

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24 Cat.C
Oil resistant : intermittent splash – permanent resistance available upon request
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

 

 

Features

Fiber countSimplex outer diameter (mm)Intermediate jacket diameter (mm)Outer jacket thickness (mm)Cable Outer Diameter (mm)Cable weight (kg/km)Pulling tension (N)
22,07,51,08,0551200
42,08,51,08,0551200
82,09,01,010,8951400
122,010,01,013,51652000
242,012,41,014,92902500

 

 

Ordering and delivery information

Fiber countP/NPackaging
2OBOK102 ff 1drum 2000m (+/-5%)
4OBOK104 ff 1drum 2000m (+/-5%)
8OBOK108 ff 1drum 2000m (+/-5%)
12OBOK112 ff 1drum 2000m (+/-5%)
24OBOK124 ff 1drum 2000m (+/-5%)

ff =  S2 for G652D, A1 for G657A1, M1 for OM1, M2 for OM2, M3 for OM3, M4 for OM4, M5 for OM5.

 

 

 

Other standards of reference

IEC 60092-370Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.50/1Type Approval Program - Optical Fibre Cables
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
IEC 60793General specifications for both multimode and single-mode optical fibres
IEC 60794general specifications for optical fibres cables

 

 

 

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.