Arctic Grade RS485 cables up to 4 pairs, armoured, SHF2

EMC screened, stranded conductor -65°C, SHF2, Fire Retardant IEC60332-3-22
ORS5A1P24Fx2/ORS5A2P24Fx2/ORS5A4P24Fx2, 01.03.2015/AP rev.0

 

Print or Download PDF

Description

    

 

Store at : -20 to +70 °C
Install at : -20 to +70 °CBend minimum : 20 times O.D.
Operate at : -65 to +80 °CBend minimum : 20 times O.D.
Pull maximum : 50N

 

 

Design

Conductor : stranded tinned copper 7×0.20mm AWG24 (0.60mm, 0.22mm2)
Insulation : polyethylene Ø1.30mm
Pair : 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown
Assembling : 1, 2 or 4 pairs assembled together into a compact core
Overall screen 1 : aluminium/polyester tape (coverage 100%) with stranded tinned copper drain wire 7×0.20mm.
Overall screen 2 : tinned copper braid (nominal coverage 85%)
Inner jacket : black Fire Retardant SHF1 material, LSZH (Ø 8.0mm)
Armour : galvanized steel wires, tinned copper or bronze wires braid (nominal coverage 85%)
Outer jacket : black Fire Retardant and UV Resistant SHF2 material, LSZH (nominal thickness 1.5mm)
Marking : APS Finland – ww/yy – ARCTIC GRADE RS485 SHF2 ARMOURED CABLE … PAIRS 24AWG 100 OHM – IEC60332-3-22 Cat A – lot + m

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Ozone resistant : IEC 60811-2-1
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC 60811, IRM 903
MUD resistant : upon request
Water absorption : IEC60811-1-3
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Cold Bend : CSA C22.2 (-65°C)
Cold Impact : CSA C22.2 (-55°C)

 

 

Electrical characteristics

Operation voltage : 100V
Test voltage : 2000V d.c. for 1 minute
Resistance of the conductor @ 20°C : ≤ 90 Ω/km
Insulation resistance @ 20°C : ≥ 1GΩxkm
Nominal Capacitance @ 800Hz : 42 pF/m
Characteristic impedance : 120 ± 15 Ω @ 1MHz
Nominal attenuation : 22 dB/km @ 1MHz

 

 

Ordering and delivery information

  Pair count P/N O.D [mm] Weight [kg/km] Packaging 
1 pair ORS5A1P24Fx2 12.2 200 drum 500m (+/-5%) 
2 pairs ORS5A2P24Fx2 12.2 200 drum 500m (+/-5%) 
4 pairs ORS5A4P24Fx2 12.2 220 drum 500m (+/-5%) 

For armour replace x with “A” for Galvanized Steel Wire Braid, “T” for Tinned Copper Wire Braid, “B” for Bronze Wire Braid.

 

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2Type Approval Program
ABS SVRRules for building and classing. Steel Vessels.
ABS SMRRules for building and classing. Steel vessels under 90 meters.
IEC 60811Insulating and sheathing materials of electric cables - Test method

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed.