Description
Store at : -20 to +70 °C
Install at : -20 to +70 °C, Bend minimum : 20 times O.D.
Operate at : -65 to +80 °C, Bend minimum : 20 times O.D.
Pull maximum : 50N
Design
Conductor : Stranded bare copper 7×0.22 AWG23 (0,28mm2)
Insulation : Cellular polyolefin
Pair : 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown (IEC 708-1)
Screen 1 : Aluminium/polyester or Aluminium/polyester/aluminium tape over each single pair
Screen 2 : tinned copper wire braid ce
Outer jacket : Grey Fire Retardant and UV Resistant SHF2 material, LSZH (nominal Ø 10.0mm)
Marking : APS Finland – ww/yy – ARCTIC GRADE SFTP Flex 4x2x23AWG Cat.7 SHF2 – IEC60332-3-22 Cat A – lot + m
Environmental properties and Fire Performances
Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Ozone resistant : IEC 60811-2-1
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC 60811, IRM 903
MUD resistant : upon request
Water absorption : IEC60811-1-3
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Cold Bend : CSA C22.2 (-65°C)
Cold Impact : CSA C22.2 (-55°C)
Electrical characteristics (IEC 60811, EN 50288-4-2)
Test voltage : 1kV d.c. or 0.7kV a.c. for 1 minute
Resistance of the conductor @ 20°C : ≤ 69,5 /km
Insulation resistance : ≥ 500 MΩxkm (100V-500V)
Nominal Capacitance @ 800÷1000MHz : 55 pF/m
Average characteristic impedance : 100 ± 5 Ω @ 100MHz
Transfer impedance : ≤15mΩ/m @ 1MHz, – ≤10mΩ/m @ 10MHz – ≤30mΩ/m @ 30MHz
Frequency (MHz) : | 1 | 4 | 10 | 16 | 20 | 32.5 | 62.5 | 100 | 155 | 200 | 300 | 600 |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Attenuation dB/100m (typical) | 2.2 | 3.8 | 5.9 | 7.4 | 8.4 | 10.5 | 15.3 | 18.1 | 23.2 | 26.6 | 33.3 | 50.1 |
NEXT dB (typical) | 100 | 100 | 95 | 90 | 90 | 90 | 85 | 82 | 80 | 77 | 71 | 67 |
PS NEXT dB (typical) | 95 | 95 | 90 | 86 | 80 | 80 | 80 | 75 | 70 | 68 | 66 | 62 |
ELFEXT dB (typical) | 96 | 93 | 90 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | |
PS ELFEXT dB (typical) | 98 | 90 | 98 | 105 | 90 | 90 | 90 | 90 | 90 | 90 | 90 | 90 |
Return Loss dB (typical) | 35 | 31 | 38 | 32 | 32 | 31 | 27 | 34 | 28 | 25 | 23 | 21 |
Ordering and delivery information
Pair count | P/N | O.D [mm] | Weight [kg/km] | Packaging |
---|---|---|---|---|
4 pairs | O7ASF4P23F2 | 10,0 | 110 | 500m or 1000m (+/-5%) |
Recommended connectivity
Keystone jack : KJ6ASTPNH (Category 6A)
RJ45 plug : P457SAPS
Panel : PPE24SU, OPPE24SU
Patchcords : PCMJ6S_
Other standards of reference
IEC 60092-370 | Electrical installations in ships: Guidance on the selection of cables for telecommunication and data. |
IEC 60092-360 | Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. |
DNV TAP 827.50/2 | Type Approval Program |
ABS SVR | Rules for building and classing. Steel Vessels. |
ABS SMR | Rules for building and classing. Steel vessels under 90 meters. |
CEI EN 50288-1 | Multi-element metallic used in analogue and digital communication and control : Generic Specification |
CEI EN 50288-2-1 | Setional specification for screened cables characterised up to 100MHz |
CEI EN 50288-5-1 | Setional specification for screened cables characterised up to 250MHz |
CEI EN 50288-4-2 | Setional speci cation for screened cables characterised up to 600MHz |
CEI EN 50289 series | Communication cables - Specifications for test methods |
IEC 60811 | Insulating and sheathing materials of electric cables - Test method |
Standards | EIA/TIA 568-C.2, ISO/IEC 11801, UL444, UL1581, UL1666 |
Applications | 100Base-TX, 100Base-T, 100VG-AnyLAN, 1000Base-TX, ATM |