Description
Store at : -20 to +70 °C
Install at : -20 to +70 °C, Bend minimum : 20 times O.D.
Operate at : -65 to +80 °C, Bend minimum : 20 times O.D.
Pull maximum : 50N
Design
Conductor : Stranded bare copper 7×0.22 AWG23 (0,28mm2)
Insulation : Cellular polyolefin
Pair : 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown (IEC 708-1)
Screen 1 : Aluminium/polyester or Aluminium/polyester/aluminium tape over each single pair
Screen 2 : tinned copper wire braid ce
Outer jacket : Grey Fire Retardant and UV Resistant SHF2 material, LSZH (nominal Ø 10.0mm)
Marking : APS Finland – ww/yy – ARCTIC GRADE SFTP Flex 4x2x23AWG Cat.6A SHF2 – IEC60332-3-22 Cat A – lot + m
Environmental properties and Fire Performances
Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission :IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Ozone resistant : IEC 60811-2-1
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC 60811, IRM 903
MUD resistant : upon request
Water absorption : IEC60811-1-3
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Cold Bend : CSA C22.2 (-65°C)
Cold Impact : CSA C22.2 (-55°C)
Electrical characteristics (IEC 60811, EN 50288-4-2)
Test voltage : 0.7kV a.c. for 1 minute
Resistance of the conductor @ 20°C : ≤ 69,5 /km
Insulation resistance : ≥ 500 MΩxkm
Nominal Capacitance @ 800÷1000MHz : 45 pF/m
Average characteristic impedance : 100 ± 5 Ω @ 100MHz
Transfer impedance : ˂ 3mΩ/m @ 10MHz
Frequency (MHz) : 1 4 10 20 31,25 62,5 100 155 200 300 400 500
Attenuation dB/100m (nominal) 1,8 3,3 5,4 7,4 9,6 13,9 17,5 22,4 24,8 30,7 35,9 40,2
NEXT dB (nominal) 95 95 92 88 87 86 84 83 82 81 80 79
ACR dB/100m (nominal) 93 92 87 81 77 72 66 61 57 50 44 39
ELFEXT dB (nominal) 90 88 87 85 81 77 72 68 65 62 59 57
Return Loss dB (nominal) 25 28 30 30 30 28 27 26 25 23 22 21
Ordering and delivery information
Pair count | P/N | O.D [mm] | Weight [kg/km] | Packaging |
---|---|---|---|---|
4 pairs | O6AASF4P23F2 | 10,0 | 110 | 500m (+/-5%) |
Recommended connectivity
Keystone jack : KJ6ASTPNH
RJ45 plug : P456SAPS
Panel : PPE24SU, OPPE24SU
Patchcords : PCMJ6S_
Other standards of reference
IEC 60092-370 | Electrical installations in ships: Guidance on the selection of cables for telecommunication and data. |
IEC 60092-360 | Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. |
DNV TAP 827.50/2 | Type Approval Program |
ABS SVR | Rules for building and classing. Steel Vessels. |
ABS SMR | Rules for building and classing. Steel vessels under 90 meters. |
CEI EN 50288-1 | Multi-element metallic used in analogue and digital communication and control : Generic Specification |
CEI EN 50288-2-1 | Setional specification for screened cables characterised up to 100MHz |
CEI EN 50288-5-1 | Setional specification for screened cables characterised up to 250MHz |
CEI EN 50288-4-2 | Setional speci cation for screened cables characterised up to 600MHz |
CEI EN 50289 series | Communication cables - Specifications for test methods |
IEC 60811 | Insulating and sheathing materials of electric cables - Test method |
Standards | EIA/TIA 568-C.2, ISO/IEC 11801, UL444, UL1581, UL1666 |
Applications | 100Base-TX, 100Base-T, 100VG-AnyLAN, 1000Base-TX, ATM |
Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed.