Description
Store at : -40 to +70 °C
Install at : -10 to +50 °C, Bend minimum : 15 times O.D.
Operate at : -30 to +70 °C, Bend minimum : 10 times O.D.
Crush maximum : 2000N/100mm
Impact maximum : 25J
Design
Bare fiber : 250µm
Buffer : 900µm tight buffer
Colour code : See table
Cable core : up to 24 tight buffered fibers are stranded together. The core is filled with waterblocking glass yarns.
Inner sheath : black SHF1 material
Armour : galvanized steel, bronze or tinnerd copper wired braid. Coverage ≥80%.
Outer jacket : black SHF1 UV-Resistant material, LSZH
Marking : APS Finland – ww/mm – Fiber Optic Cable AICI “fiber count and type” – SHF1 IEC60332-3-22 Cat A – TK/lot + meter
Environmental properties and Fire Performances
Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : NO
Ozone resistant : upon request
Weather resistant : upon request
LSZH SHF2 : upon request
Oil resistant : intermittent splash – permanent resistance available upon request
MUD resistant : upon request
Water absorption : IEC60502
Water penetration : IEC 60794-1-2-F5-B (inner core only)
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Ordering and delivery information
Fiber count | SM | OM1 | OM2 | OM3 | OM4 | Packaging |
---|---|---|---|---|---|---|
2 | OAICI02S21 | OAICI02M11 | OAICI02M21 | OAICI02M31 | OAICI02M41 | drum 2000m (+/-5%) |
4 | OAICI04S21 | OAICI04M11 | OAICI04M21 | OAICI04M31 | OAICI04M41 | drum 2000m (+/-5%) |
8 | OAICI08S21 | OAICI08M11 | OAICI08M21 | OAICI08M31 | OAICI08M41 | drum 2000m (+/-5%) |
12 | OAICI12S21 | OAICI12M11 | OAICI12M21 | OAICI12M31 | OAICI12M41 | drum 2000m (+/-5%) |
24 | OAICI24S21 | OAICI24M11 | OAICI24M21 | OAICI24M31 | OAICI24M41 | drum 2000m (+/-5%) |
Colour code of fibers
01 | 02 | 03 | 04 | 05 | 06 | 07 | 08 | 09 | 10 | 11 | 12 | |
Blue | Orange | Green | Brown | Grey | White | Red | Black | Yellow | Violet | Pink | Turquoise | |
13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | |
Blue/BR | Orange/BR | Green/BR | Brown/BR | Grey/BR | White/BR | Red/BR | Black/BR | Yellow/BR | Violet/BR | Pink/BR | Turquoise/BR |
Features
Fiber count | Inner jacket thickness (mm) | Inner jacket diameter (mm) | Outer jacket thickness (mm) | Cable Diameter (mm) | Cable weight (kg/km) | Pulling tension (N) |
---|---|---|---|---|---|---|
2 | 1.0 | 4.8 | 1.0 | 8.0 | 95 | 1000 |
4 | 1.0 | 5.2 | 1.0 | 8.5 | 105 | 1000 |
8 | 1.0 | 6.0 | 1.0 | 9.4 | 125 | 1000 |
12 | 1.2 | 6.7 | 1.3 | 10.3 | 145 | 1500 |
24 | 1.2 | 8.5 | 1.3 | 12.1 | 185 | 2000 |
Other standards of reference
IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.50/1 Type Approval Program - Optical Fibre Cables
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
IEC 60793 General specifications for both multimode and single-mode optical fibres
IEC 60794 general specifications for optical fibres cables
Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.